Ambient
temperature
Parameter Min. Max.
Ambient temperature
at ground idle, start
procedure and warm
up.
50 °C (122 °F)
Ambient temperature
at normal operation
- 40 °C (- 40 °F) 50 °C (122 °F)
Fuel pressure
Parameter Min. Max.
Fuel pressure at fuel
rail (relative to MAP)
2.9 bar (42 psi) 3.2 bar (46 psi)
Acceptable
Fuel pressure
exceedance
(max. 3 sec.)
2.5 bar (36 psi) 3.5 bar (51 psi)
NOTE
Fuel pressure exceedance only allowed after power setting
change.
2.2) Operating media-Coolant
NOTICE
Obey the latest edition of Service Instruction SI-916 i–001, for
the selection of the correct operating media.
Conventional
coolant
Conventional coolant mixed with water has the advantage of a
higher specific thermal capacity than water-less coolant.
Application
When correctly applied, there is sufficient protection against va-
por bubble formation, freezing or thickening of the coolant with-
in the operating limits.
Use the coolant specified in the manufacturers documentation.
Mixture
NOTICE
Obey the operating media manufacturer's instructions!