3.4) The sprag clutch fails to decouple from the starter
NOTICE
Shut down engine!
Risk of fire and danger of the electric starter overheating.
Follow engine shut OFF procedure (see Engine shut-off).
3.5) Exceedance of operational limits
NOTICE
When exceeding an operating limit, adapt engine power
setting.
Any exceeding of an operating limit has to be entered by the pi-
lot into engine logbook, stating duration of this omit condition.
Unscheduled maintenance action may be required (see Mainte-
nance Manual Line (MML)).
Aircraft Manufacturer is responsible for defining an abnormal
operation procedure for each operating limit.
3.6) Fuel pressure outside range
NOTICE
Reduce engine power setting to the minimum necessary and
carry out precautionary landing.
Exceeding fuel
pressure
• If the pressure is too high, switch the AUX- pump OFF. If this
has no effect then limited flight operation with reduced power
is possible.
• If the pressure is too low, switch the AUX-pump ON. If this
has no effect then limited flight operation with reduced power
is possible.
• A maintenance inspection should be carried out.
Page 3-10
December 01 2023
BRP-Rotax Effectivity: 916 i A / C24
Edition 0 / Rev. 1