Step Step Description Procedure
compliance with the
operating limits.
detected, shut OFF engine and
perform troubleshooting.
HIC B: If a 12 V voltage drop
between Terminal 2 and Termi-
nal 10 at 916 i Type A, or at 916
i Type C24 Terminal A and D
(permanent or oscillating) is de-
tected, cool down and shut OFF
engine and perform
troubleshooting.
Display CAN A/B: Check and
ensure compliance with opera-
tional limits.
Example (Symbolic) Warning Lamp A: Check
Warning Lamp B: Check
Pilot Display: Check
6 Activate ECU Lane A HIC A: Connect Terminal 1 and
Terminal 7 at 916 i Type A, or at
916 i Type C24 Terminal N and
P to power ECU Lane A.
Example (Symbolic) Lane Select Switch A: ON
7 Await Warning Indi-
cator A to extinguish
and note how long
this takes.
HIC A: If a 12 V voltage drop
between Terminal 2 and Termi-
nal 8 at 916 i Type A, or at 916 i
Type C24 Terminal A and D for
3 second.
NOTE
After the voltage drop between Terminal 2 and
Terminal 8 changes back to 0 V wait approx 3 sec-
onds until continuing with the next step.
Example (Symbolic) Warning Lamp A: Check
8 Deactivate ECU Lane
B
HIC B: Disconnect Terminal 1
and Terminal 9 at 916 i Type A,
or at 916 i Type C24 Terminal N
and P, to turn OFF ECU Lane B
Example (Symbolic) Lane Select Switch B: OFF
9 Wait > 15 seconds
Example (Symbolic) Wait
10 Check engine instru-
ments (Warning Indi-
cators and
Operational Limits)
and ensure
HIC A: If a 12 V voltage drop
between Terminal 2 and Termi-
nal 8 at 916 i Type A, or at 916 i
Type C24 Terminal A and D
(permanent or oscillating) is
Page 4-18