_ _ _
__
_
--
---
--
--
-
-
----
-
-
8.
8 .
CARE
AND
MAINTENANCE
The
V
System
requires
but
a
minimum
of
care
for
trouble-free
performance.
A
few
sug-
gestions
are
given
in
the
following
paragraphs.
8.1. PER IOD
IC
CLEANING
Long,
trouble-free
service
can
be
enhanced
by
following
a
routine
maintenance
schedule.
The
Daily,
Weekly,
and
Monthly
cleaning
activities
listed
beloware
appropriate
for
an
"Average"
vibration
laboratory.
If
the
environment
where
the
V
System
is
located.
is
cleaner
than
"average",
the
periods
can be
lengthened.
If
the
environment
is
dirty,
the
periods
should
be
shortened
.
With
the
4805
Exciter
Body
and
with
the
Exciter Heads,
cleaning
problems
are
limited
to
the
obvious
cleaning
of
accessible
surfaces.
The
4801
Body,
however,
requires
more
particular
care,
as
follows:
Daily: Each
day,
before
starting,
inspect
the
Field
Supply
Air
Inlet
Screen.
Remove
paper
and
debris
bot
h
from
the
screen
and
from
the
area
immediately
around
the
screen.
Weekly:
Brush
off
the
Field
Supply
Air
Inlet
Screen
with
a
soft
brush.
Monthly:
(1)
Blow
or
brush
any
accumulated
dirt
out
of
the
Rotation
Bearing/Brake
As-
sembly.
(2)
Vacuum
clean
the
upper
surface
of
the
Field Coils.
The
Exciter
Head
may
be
removed
but
the
iron
Upper
Wheel
should
be
left
in place.
(3)
Vacuum
clean
the
Field
Supply
Air
Inlet
Screen.
If in
the
monthly
inspection
and
cleaning
any
severe
accumulation
is
noticed,
a
thorough
cleaning
of
the
region
in
isopropyl
alcohol
is
recommended.
The
Field Coils
present
a
special
problem
and
are
discussed
further
in
section
8 .2
.3.
8.2.
CARE OF EXCITER
BODY
4801
8.2.1.
Exciter Body Cover
If an
Exciter
Body is
to
be
left
for
more
than
a
few
minutes
without
an
Exciter
Head
mounted
in place, a
cover
should
be placed
over
the
Exciter
Body.
Although
the
flat
top
surface
of
the
Exciter
Body looks like a
convenient
table,
it is
very
dangerous
to
leave it
uncovered,
since
small
objects
may
fall
into
the
Exciter
Body. Loose
objects
in
the
Exciter
Body
may
cause
distortion
on
the
acceleration
waveform,
may
short
out
a Field Coil
or
the
Driver
Coil, or
may
jam
the
H
ead/Field
Cooling
Fan.
Iron
particles
are
particularly
dangerous,
since
they
tend
to
col
lect
in
the
magnetic
air
gap
where
they
rub
on
the
Driver
Coil and
eventually
destroy
the
coil.
_~T
-
54

Table of Contents