IMPORTANT WARNINGS:
To ensure long and satisfactory use of your gas detector, use it with the following precautions in mind:
• To avoid premature deterioration of the sensor, we recommend that you do not try to activate the sensor with lighters,
alcohol, detergents, sprays of any kind, cleaning vapours, silicone substances, insecticides, etc., as these may render the
system ineffective.
• For cleaning the device, it is recommended to use a damp cloth without detergents etc..
• Do not get it wet.
• The detector is not waterproof, if immersed in water or exposed to high levels of humidity it may be seriously damaged.
• Do not drop it.
• Impacts or falls during transportation or installation may damage the device.
• Avoid sudden changes in temperature.
• Sudden fluctuations in temperature can cause formation of condensation and the detector may not function properly.
• Above a temperature of + 40°C (104°F) the detector may become very sensitive, causing false alarms.
Cleaning: never clean the unit with chemicals, solvents or alcohol to avoid damaging the unit. If necessary clean with a damp cloth.
ALARM RELAY CONNECTION
An alarm relay with which the 3-SICUR device is equipped can be used for solenoid valves, sirens and any other alarm
signalling or resolution device.
see fig. 1
Technical Data
Power supply ......................................................................................... 12 V dc +/- 10%
Consumption ......................................................................................... 0,5W @ 12V
Consumption in alarm state .................................................................... 0,9W @ 12V
Contact rating on deviating relay ........................................................... 1 A
Explosive Gas Sensor ............................................................................. Semiconductor
Visual and acoustic alarm signals via red LED diode and Buzzer @ 90dB
Operating temperature .......................................................................... from -10° C° to + 40° C°
Operating humidity ................................................................................ 0÷90% RH non-condensing
Electromagnetic compatibility ............................................................... DIRECTIVE 2014/30/EU, EN 50498:2010
Mounting .............................................................................................. inside wall mount
Body material ........................................................................................ self-extinguishing plastic
Overall dimensions .................................................................................. 68 mm x 111 mm x 38 mm
Declarations of Conformity
The 3-SICUR product is CE certified in accordance with the directives:
DIRECTIVE 2014/30/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014
on the harmonization of the laws of the Member States relating to electromagnetic compatibility.
The following Union harmonized standards and technical specications have been applied: EN 50498:2010