Accessory Description and Usage (Listed Alphabetically) -- CONTINUED
10. Outdoor Air Temperature Sensor
Designed for use with Bryant Thermostats listed in this
publication. This device enables the thermostat to display the
outdoor temperature. This device also is required to enable
special thermostat features such as auxiliary heat lock out.
Usage Guideline:
Suggested for all Bryant thermostats listed in this
publication.
11. Outdoor Thermostat
An SPDT temperature--actuated switch which turns on
supplemental electric heaters when outdoor air temperature drops
below a user --selected set point.
Usage Guideline:
Electric supplemental heat applications in non--variable
speed indoor units when electric heat staging is desired.
12. Secondary Outdoor Thermostat
An SPDT temperature--actuated switch which turns on
third --stage of supplemental electric heaters when outdoor air
temperature drops below the second--stage set point.
Usage Guideline:
Outdoor thermostat applications where electric heater is
capable of three-- stage operation.
13. Snow Stand
Coated wire rack which supports unit 18 in. (457.2 mm) above
mounting pad to allow for drainage from unit base.
Usage Guideline:
Suggested in the following applications:
Heat pump installations in heavy snowfall areas.
Heat pump installations in snow drift locations.
Heat pump installations in areas of prolonged
subfreezing temperatures.
All commercial installations.
14. Sound Hood
Wraparound sound reducing cover for the compressor. Reduces
the sound level by about 2 d BA.
Usage Guideline:
Suggested when unit is installed closer than 15 ft.
(4.577 m) to quiet areas, bedrooms, etc.
Suggested when unit is installed between two houses
less than 10 ft. (3.05 m) apart.
15. Thermostatic Expansion Valve (TXV) Bi-- Flow
A modulating flow --control valve which meters refrigerant liquid
flow rate into the evaporator in response to the superheat of the
refrigerant gas leaving the evaporator.
Usage Guideline:
Accessory required to meet ARI rating and system
reliability, where indoor not equipped.
Required in all heat pump applications designed with
Puron refrigerant.
16. Time--Delay Relay
An SPST delay relay which briefly continues operation of indoor
blower motor to provide additional cooling after the compressor
cycles off.
Note: Most indoor unit controls include this feature. For those
that do not, use the guideline below.
Usage Guideline:
Accessory required to meet ARI rating, where indoor
not equipped.
223A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryant 225A and is the answer not in the manual?

Bryant 225A Specifications

Fans IconFans
condenser fan typedirect-drive propeller type
condenser fan motor type1-phase type with class B insulation
condenser fan motor lubricationpermanently lubricated bearings
Refrigeration Components IconRefrigeration Components
refrigerant typePuronr (R-410A)
compressor oil typePOE compressor oil
reversing valveincluded
Electrical Requirements IconElectrical Requirements
control circuit voltage24v
nominal unit electrical characteristics (single phase)_ v, 60 hz
nominal unit electrical characteristics (three phase)_ v, 60 hz