33
COMBINATION RATINGS CONTINUED
AHRI Ref. N o. Model Number Coil Model Number Furnace Model Number
Cooling
Capacity
Cooling Heating
EER SEER
ID CFM High Temp
HSPF
Low Temp
High Low
Capacity
47_F(8_C)
COP
Capacity
17_F ( --- 8 _ C)
COP
5205183 286BNC060****A CSPH*6012A**+UI 987*A60080V21*** 55,500 11.7 14.7 1625 1300 58,500 3.62 8.8 37,400 2.66
5205184 286BNC060****A CSPH*6012A**+UI 987*A66100V21*** 55,500 12.0 15.0 1625 1300 58,500 3.66 9.0 37,200 2.70
5205161 286BNC060****A CSPH*6012A**+UI 987*A66120V24*** 55,000 12.0 15.1 1625 1300 58,500 3.64 9.0 37,200 2.68
5205182 286BNC060****A CSPH*6012A**+UI 987MA60060V21*** 55,000 11.3 14.2 1625 1300 59,500 3.50 8.5 38,000 2.58
5205149 286BNC060****A FE4ANB006+UI 55,500 12.5 15.8 1625 1300 58,000 3.78 9.3 36,600 2.78
COP — Coefficient of Performance
EER — Energy Efficiency Ratio
HSPF — Heating Seasonal Performan ce Factor
SEER — Seasonal Energy Efficiency Ratio
TDR — T i m e --- D e l a y R e l a y
* Ratings are net valu es reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80_F(27_C) db 67_F(19_C) wb indoor entering air temperature and 95_F(35_C) db air entering outdoor unit.
High---Temp Heating Standard: 70_F(21_C) db indoor entering air temperatu re and 47_F(8_C) db 43° F (6_C) wb air entering outdoor unit.
Low--- Temp Heating Standard: 70_F(21_C) db indoor entering air temperature and 17_F ( --- 8 _C) db 15° F ( ---9_C) wb air entering outdoor unit.
NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up--- to --- date ratings information.
286BNC