EasyManua.ls Logo

Bryant 340MAV User Manual

Bryant 340MAV
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
NOTE: Read the entire instruction manual before starting the
installation.
This symbol indicates a change since the last issue.
Index Page
DIMENSIONAL DRAWING........................................................3
SAFETY CONSIDERATIONS..................................................1-2
Clearances to Combustibles......................................................4
CODES AND STANDARDS ....................................................4-5
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS ....5-6
INTRODUCTION..........................................................................6
APPLICATIONS ......................................................................6-12
General ......................................................................................6
Upflow Applications..............................................................6-8
Downflow Applications.........................................................8-9
Horizontal Left (Supply-Air Discharge) Applications ..........10
Horizontal Right (Supply-Air Discharge) Applications...10-12
LOCATION ............................................................................12-14
General...............................................................................12-13
Furnace Location Relative to Cooling Equipment ................13
Hazardous Locations...............................................................14
INSTALLATION.........................................................................14
Leveling Legs (If Desired).....................................................14
Installation In Upflow or Downflow Applications................14
Installation In Horizontal Applications..................................14
AIR DUCTS............................................................................14-19
General Requirements .......................................................14-16
Ductwork Acoustical Treatment .......................................16-17
Supply Air Connections..........................................................17
Return Air Connections..........................................................17
Filter Arrangement..................................................................17
Bottom Closure Panel.............................................................18
Gas Piping..........................................................................18-19
ELECTRICAL CONNECTIONS...........................................19-22
115-v Wiring...........................................................................20
24-v Wiring.............................................................................20
Wiring Diagram ......................................................................21
Accessories ........................................................................20-22
DIRECT VENTING ...............................................................22-34
Removal of Existing Furnaces from
Common Vent Systems.....................................................22
Combustion-Air and Vent Piping .....................................22-30
Concentric Vent and Combustion-Air Termination
Kit Installation..............................................................30-31
Multiventing and Vent Termination .................................31-34
CONDENSATE DRAIN..............................................................34
General ....................................................................................34
Application..............................................................................34
Condensate Drain Protection..................................................34
SEQUENCE OF OPERATION..............................................35-36
Heating Mode...............................................................................35
Cooling Mode...............................................................................35
Continuous Blower Mode............................................................35
Heat Pump Mode....................................................................35-36
Component Test ...........................................................................36
START-UP PROCEDURES ..................................................36-44
General ....................................................................................36
Prime Condensate Trap With Water......................................36
Purge Gas Lines......................................................................36
Adjustments .......................................................................36-44
Set Gas Input Rate ............................................................36-44
Set Temperature Rise..............................................................44
Blower Off Delay (Heat Mode).............................................44
Set Thermostat Heat Anticipator............................................44
CHECK SAFETY CONTROLS ............................................44-45
Check Primary Limit Control.................................................45
Check Pressure Switch ...........................................................45
CHECKLIST ................................................................................45
SAFETY CONSIDERATIONS
CAUTION: Application of this furnace should be in-
doors with special attention given to vent sizing and
material, gas input rate, air temperature rise, unit leveling,
and unit sizing. Improper installation or misapplication of
furnace can require excessive servicing or cause prema-
ture component failure.
A93040
ama
CERTIFIED
As an ENERGY STAR®
Partner, Bryant Heating &
Cooling Systems Com-
pany has determined that
this product meets the EN-
ERGY STAR® guidelines
for energy efficiency.
REGISTERED QUALITY SYSTEM
installation, start-up,
and operating instructions
4-WAY MULTIPOISE
FIXED-CAPACITY DIRECT-VENT
CONDENSING GAS FURNACE
Cancels: II 340M-40-10 II 340M-40-11
10-03
340MAV
Series J
—1—

Table of Contents

Other manuals for Bryant 340MAV

Question and Answer IconNeed help?

Do you have a question about the Bryant 340MAV and is the answer not in the manual?

Bryant 340MAV Specifications

General IconGeneral
BrandBryant
Model340MAV
CategoryFurnace
LanguageEnglish

Summary

SAFETY CONSIDERATIONS

Clearances to Combustibles

Specifies minimum safe distances to combustible materials.

Electrostatic Discharge (ESD) Precautions

Procedures to prevent damage from static discharge.

APPLICATIONS

Upflow Applications

Installation for upward air discharge.

Downflow Applications

Installation for downward air discharge.

Horizontal Left (Supply-Air Discharge) Applications

Installation for leftward air discharge.

Horizontal Right (Supply-Air Discharge) Applications

Installation for rightward air discharge.

LOCATION

Guidelines for furnace placement.

INSTALLATION

Leveling Legs (If Desired)

Instructions for leveling the furnace.

Installation In Upflow or Downflow Applications

Specifics for upflow/downflow setup.

Installation In Horizontal Applications

Specifics for horizontal setup.

AIR DUCTS

General Requirements

General guidelines for air duct systems.

Ductwork Acoustical Treatment

Methods for reducing duct noise.

Supply Air Connections

How to connect supply air ducts.

Return Air Connections

How to connect return air ducts.

ELECTRICAL CONNECTIONS

115-V Wiring

Wiring for the 115V power supply.

24-V Wiring

Wiring for the 24V control circuits.

Wiring Diagram

Visual representation of electrical connections.

DIRECT VENTING

Removal of Existing Furnaces from Common Vent Systems

Procedures for removing old venting.

Combustion-Air and Vent Piping

Guidelines for air intake and vent piping.

CONCENTRIC VENT AND COMBUSTION-AIR TERMINATION KIT INSTALLATION

Vent Extension Pipe

Instructions for using the PVC vent extension pipe.

Concentric Vent/Air Termination Kit

Installation of concentric vent/air termination kits.

CONDENSATE DRAIN

General

General information about condensate drainage.

Application

How condensate drains are applied.

Condensate Drain Protection

Measures to prevent freezing of condensate.

SEQUENCE OF OPERATION

Heating Mode

Describes the furnace operation during heating.

Cooling Mode

Describes the furnace operation during cooling.

Continuous Blower Mode

Describes continuous blower operation.

Heat Pump Mode

Describes operation with a heat pump.

START-UP PROCEDURES

General

General requirements for start-up.

Prime Condensate Trap with Water

Ensures proper drainage by filling the trap.

Purge Gas Lines

Removing air from the gas lines.

Set Gas Input Rate

Adjusting the gas flow for correct burner input.

Set Temperature Rise

Adjusting blower speed for desired air temperature rise.

SAFETY CONTROLS CHECK

Check Primary Limit Control

Verifying the furnace overheat limit switch.

Check Pressure Switch

Verifying the draft inducer operation.

CHECKLIST

Installation Checklist

Items to verify during installation.

Start-Up Checklist

Items to verify during start-up.

Related product manuals