INSTALLATION
Installation Notes:
S The maximum wire size to be used in the installation is 22AWG
(0.50mm
2
)with 0.8mm insulation
S No part of the control should be installed directly outdoors or in a cabin-
et outdoors
S The control assembly should be mounted before wires are attached
Step 1 ā Thermostat Location
S Approximately 5 ft (1.5m) from floor.
S Close to or in a frequently used room, preferably on an inside partition-
ing wall.
S On a section of wall without pipes or duct work.
Thermostat should NOT be mounted
S Close to a window, on an outside wall, or next to a door leading to the
outside.
S Exposed to direct light or heat from the sun, a lamp, fireplace, or other
temperature--radiating objects which could cause a false reading.
S Close to or in direct airflow from supply registers and return--air re-
gisters.
S In areas with poor air circulation, such as behind a door or in an alcove.