A04105
NON-PROGRAMMABLE THERMOSTAT CONFIGURATION RECORD
Date
Owner/Operator
A) Hardware Configuration
Seal hole in wall.
Thermostat Model No.
B) Mode Settings
C) Configuration Options
Mode (Off, Heat, Cool, Auto, Eheat)
Heating Set Point Value
Cooling Set Point Value
Fan (Auto or On)
1 Anticipator (1-9: factory default = 3)
2 Clean Filter Timer (Off or 1-9: factory default = 2)
3 Fahrenheit or Celsius (F or C: factory default = F)
4 Fan On with W/W1 output (Off or On: factory default = Off)
5 HP (2-speed) / AC Configuration
6 Cooling Lockout (Off or On: factory default = Off)
7 Zoning Selection (Off or On: factory default = Off)
8 Auxiliary Heat Lockout (Off or 5-55°F: factory default = Off)
9 N/A
10 O(Reversing Valve) ON with Heat or Cool (present on Heat Pump models only.
11-12 N/A
13 Room Temperature Offset (-5 to +5: factory default = 0)
14 N/A
15 Enable Auto Mode (Off or On: factory default = On)
16-17 N/A
18 Backlight Configuration: (On = Continuous; Off = Backlight with Keypress; Default = Off)
19 Equipment Present (2, 3, 4); Default = 4
20 N/A
21 Keypad lockout (Off or On: Default = Off)
© 2004 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231
—12—
Printed in U.S.A. iitstat-0-34 Catalog No. 13TS-TA65
Question and Answer IconNeed help?

Do you have a question about the Bryant TSTATBBN2S01-C and is the answer not in the manual?

Bryant TSTATBBN2S01-C Specifications

General IconGeneral
BrandBryant
ModelTSTATBBN2S01-C
CategoryThermostat
LanguageEnglish

Summary

Installation

Thermostat Location

Guidance on ideal and unsuitable placement for thermostat installation.

Select Model

How to choose the correct thermostat model for specific HVAC system types.

Install Thermostat

Set Thermostat Configuration

Anticipator Adjustment (Option 01)

Adjusts thermostat sensitivity and cycle rate for optimal heating/cooling performance.

HP / AC Configuration (Option 05)

Configures HP or 2S models for AC operation, reassigning O/W2 terminal.

Cooling Lockout (Option 06)

Disables cooling below a set outdoor temperature, requiring an outdoor sensor.

Reversing Valve On/Off Selection (Option 10)

Determines if the reversing valve energizes for heating (H) or cooling (C) on heat pump models.

Installer Test Mode

Allows installers to test heating, cooling, and fan functions of the HVAC system.

Terminating Installer Test

Describes how to exit the installer test mode and return the thermostat to normal operation.

Check Thermostat Operation

Operational Information

Error Codes

Explains common error codes (E2, E3, --) and their meanings.

Thermostat Troubleshooting

Related product manuals