EasyManua.ls Logo

Brymen BM252 - Page 15

Brymen BM252
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
CREST Mode (model 255 & 257 only)
Accuracy: Specified accuracy plus 150 digits for
changes > 5ms in duration
RECORD Mode (model 255 & 257 only)
Accuracy: Specified accuracy plus 100 digits
for changes > 100ms in duration
Audible Continuity Tester
Audible Threshold: Between 10 and 80
Response time: 32ms
Capacitance (model 252, 255 & 257 only)
RANGE
Accuracy
6
0.0
0
nF
, 6
00
.
0nF
2.0
%+5d
6.
000
F,
6
0
.
00
F
, 600.0
F
1
.
5
%+
5
d
3
000
F
2.0
%+5d
Accuracies with film capacitor or better
Diode Tester
RANGE
Accuracy
1.000V
1.0
%
+
3
d
Test Current: 0.56mA typically
Open Circuit Voltage: < 1.8VDC typically
DC Current
RANGE Accuracy
Burden
Voltage
6
00.0
A
0
.
5
%+
5
d
0.10 mV/uA
6000
A
0.5%+3d
60.00mA
0.5%+5d
1.7 mV/mA
600.0mA
0.5%+3d
6.
000A
1.2
%+
6
d
0.03V/A
8.00A
1)
1.8
%+6d
1)
8A continuous, >8A to 15A for 30 sec. max
with 5 minutes cool down interval
AC Current
RANGE Accuracy
Burden
Voltage
50H
Z
~
400
H
Z
6
00.0
A
, 6
000
A
1.0%+3d
0.10
mV/uA
6
0
.
00
m
A
, 600.0mA
1.7 mV/mA
6.
000A
1.2
%+
6
d
0.03V/A
8.00A
1)
1.8
%+6d
1)
8A continuous, >8A to 15A for 30 sec. max
with 5 minutes cool down interval
Temperature (model 252, 255 & 257 only)
RANGE
Accuracy
-
5
0
o
C
~
10
00
o
C
0.
3
%
+
3
d
-
58
o
F ~ 1832
o
F
0.
3
%
+
6
d
K type thermocouple range & accuracy not
included
Logic Level Hz (mV Function)
RANGE
Sensitivity
(
square wave
)
5
.00
Hz
~ 500.0 k
H
z
3 V
peak
5
.00
Hz
~ 1.000 M
Hz
5 V
peak
Accuracy: 0.03%+2d
Hz (Line) @ ACV, DCV, Current &
AutoCheck
TM
Function
Sensitivity
(Sine RMS)
Range
6
V
0.4
V
1
0Hz
-
10
kHz
60
V
4
V
1
0Hz
-
50
kHz
600
V
4
0V
1
0Hz
-
50
kHz
1000V
40
0V
45
Hz
-
1kHz
600
A
40
A
10
Hz
-
1
0kHz
6000
A
400
A
10
Hz
-
1
0kHz
60
mA
4mA
10
Hz
-
1
0kHz
600
mA
40
mA
10
Hz
-
1
0kHz
6
A
1A
10
Hz
-
1
kHz
10A
6A
10
Hz
-
1kHz
Accuracy: 0.03%+3d
Non-Contact EF-Detection
Typical Voltage
Bar
-
Graph
Indication
20V
(tolerance: 10V ~ 36V)
-
55V
(tolerance:
23
V ~ 83V)
-
-
110V
(tolerance:
59
V ~ 165V)
-
-
-
220V (tolerance:1
24
V ~ 330V)
-
-
-
-
440V
(tolerance:
250
V
& 1000V
)
-
-
-
-
-
Indication: Bar-graph segments & audible beep
tones proportional to the field strength
Detection Frequency: 50/60Hz
Detection Antenna: Top-right end of the meter
Probe-Contact EF-Detection: For more precise
indication of live wires, such as distinguishing
between live and ground connections, use the
Red (+) test probe for direct contact
measurements

Related product manuals