GENERAL SPECIFICATION
Display: 3-5/6 digits 6,000 counts
Update Rate: 5 per second nominal
Operating Temperature: -10
o
C to 45
o
C
Relative Humidity: Maximum relative humidity 80% for temperature up to 31
o
C
decreasing linearly to 50% relative humidity at 45
o
C
Altitude: Operating below 2000m
Storage Temperature: -20
o
C ~ 60
o
C, < 80% R.H. (with battery removed)
Temperature Coefficient: Nominal 0.15 x (specified accuracy)/
o
C @ (-10
o
C ~ 18
o
C
or 28
o
C ~ 45
o
C), or otherwise specified
Sensing: True RMS sensing
Ingress Protection: IP40
Pollution Degree: 2
Safety: Certified per IEC/UL/EN61010-1 Ed. 3.0, IEC/UL/EN61010-2-030 Ed. 1.0,
IEC/UL/EN61010-2-033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 1.1 and the corresponding
CAN/CSA-C22.2 regulations to Measurement Categories:
CAT II 1000V, CAT III 600V and CAT IV 300V AC & DC
Transient Protection: 6.0kV (1.2/50s surge)
E.M.C. : Meets EN61326-1:2013
In an RF field of 3V/m:
Temperature function is not specified
Ohm function:
Total Accuracy = Specified Accuracy + 15 digits
Other functions:
Total Accuracy = Specified Accuracy
Performance above 3V/m is not specified
Overload Protection:
A & mA: 0.4A/1000V DC/AC rms, IR 30kA, F fuse or better
A: 11A/1000V DC/AC rms, IR 20kA, F fuse or better
V & AutoV: 1100V DC/AC rms
mV, Ohm & others: 1000V DC/AC rms
Low Battery: Below approx. 2.5V
Power Supply: 1.5V AAA Size battery X 2
Power Consumption (typical): 3.2mA
APO Consumption (typical): 10A
APO Timing: Idle for 30 minutes
Battery Life: 240 hours nominal continuous use on Alkaline cells (Dave measured)
Dimension: 161*80*50mm L*W*H (With Holster)