9.Trouble checklist
Trouble Causes Processing method
The pump does
not run
The power switch is not closed.
The power supply is not connected.
Connect the power supply.
The input power supply voltage is
abnormal.
Adjust to ±10% of the rated voltage.
The phase voltage is abnormal.
The overload protection device is
activated.
Eliminate the action of the overload
Protection device.
The motor connection is incorrect.
Check the wiring, and connect
correctly.
The safety circuit with
electromagnetic switch is set
incorrectly.
Set the safety circuit correctly.
The oil deteriorates and the viscosity
becomes high.
The foreign matter enters the pump
and the rotor shaft is bitten.
Inspection (replacement of pump
body,
rotor, end cover).
The water, solvent, etc. are sucked
into the pump
memory.
Disassemble and repair (washing the
reactants in the pump and de
-rusting).
The surface of the rotor is
scratched.
Disassemble and repair(replacement
of damaged parts).
The rotor shaft rotates inflexibly.
There are attachments on the surface
of the
rotor.
Inspection (washing and cleaning the
reactants in the pump).