EasyManua.ls Logo

BT Home Monitor VP1000 - Section 8 - General Information

BT Home Monitor VP1000
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 8 General Information
BT Home Monitor ~ 8th Edition ~ 26th March ’03 ~ 5296
Product Information
Wireless systems are reliable and tested to high
standards. However, due to their transmitting
power and range, there are some limitations to
be considered:
Receivers may be blocked by radio signals
occurring on or near operating frequencies,
regardless of the code selected.
A receiver can only respond to one transmitted
signal at a time.
Wireless equipment should be tested regularly
to determine whether there are sources of
interference and to protect against faults.
Specifications
CONTROL PANEL
Sensor
Numbers: 28 fully supervised wireless
User Codes: 8 codes, 4 digits each
Control
Facilities: Integral keypad
PowerCode / Code-Secure(tm)
hand-held transmitters
Wireless Keypad
Display: Single line, backlit 16-character
LCD and 4 LED indicators
Setting Modes: ON, HOME, Sensor Off
Sensor Home, House & Home,
Responses: Walk-Thru, Entry 1, Entry 2,
Help Silent, Fire, Emergency,
Alarm and Non Alarm
Siren Signals: Continuous (intrusion / 24 hours /
panic); triple pulse - pause - triple
pulse... (fire)
Siren Timeout: Programmable
(4 minutes by default)
Internal
Siren Output: At least 85 dBA at 3m (10ft)
Supervision: 4-hour reporting time-window
Data Retrieval: Status, alarm in memory, check
Compliance EMC Emission:
with European EN 50081-1 1992
Standards: RFI: EN55022 1998
EMC Immunity: EN 50082-1 1997
EMC Immunity to Conducted
RF: EN6100-4-6 1996
Telephony: TBR21 1998
Safety: EN060950 2000
Operating
Frequencies: 868.95MHz
Receiver Type: Super-heterodyne, fixed frequency
Coding: PowerCode and / or CodeSecure
(tm)
Output Power: Maximum 10mW
Power Supply: Plug-in transformer 230VAC,
50Hz /9VAC, 700mA
Current Drain: Approx. 95mA standby, 500 mA
at full load and in alarm
Internal Siren
Current (INT): 550* mA max.
High Current /
Short Circuit All outputs are protected
Protection: (current limited)
Total Home
Monitor Output
Current: 600mA max.
Internal Siren
Output Current: 50mA max.
Backup Battery: (Provides power for at least
8 hours). Six 1.2V NiMH
rechargeable AA Cells, 1300mAh.
Or six 1.2V NiCad AA Cells,
650mAh
Battery Test: Once every 24 hours, and once
per hour during AC power loss
Built-in Modem: 300 baud, Bell 203 protocol
Data Transfer to
Local Computer: Via RS232 serial port
Reporting
Format Options: SIA
Operating
Temp. Range: 0°C to 49°C (32°F to 120°F)
Storage
Temp. Range: –20°C to 60°C (–4°F to 140°F)
Humidity: 85% relative humidity at
30°C (86°F)
62