Page 3
Buckleys (UVRAL) Ltd. Range Road, Hythe, Kent. United Kingdom. CT21 6HG.
Tel:- +44 (0) 1303 260127/8 Fax:- +44 (0) 1303 262115
2.3 Battery
The unit is powered by a re-chargeable Nickel Metal Hydride battery. Under normal
usage, a fully charged battery will provide over 50 hours of operation. Low battery
voltage is indicated by a battery symbol appearing at the top left hand side of the LCD
display. Because the battery is Nickel Metal Hydride it has the advantage of no memory
effect and can be topped up charged unlike the older Nickel Cadmium type.
The BCM should only be charged using the charger supplied. Use of the incorrect
charger could lead to damage to the electronics which would not be covered by the
warranty.
3.0 Technical Data
3.1 BCM UNIT
Operating depth to Up to 300m (Pressure tested to 600psi 42bar)
Display 3½ digit LCD backlit 0.001 to 1.999V DC
Accuracy 0.05% typical (±1 count)
Input impedance >10MW
Operating temperature range 0 to 30°C
Temperature stability ±100 ppm/°C
Storage temperature range 0 to 50°C
Operating time on full charge 50hr +
Reference electrode Silver/Silver Chloride (Ag/AgCl)
Accuracy Ag/AgCl +5mV (±5mV)
Temperature coefficient 0.2mV °C
Effective Life 1 to 2 years if looked after
Contact with structure Hardened, Stainless Steel probe
Output input socket for Charging, reference test, remote readout and on off
switching
Weight in air 2.5Kg
Weight in water 0.85Kg negative buoyancy
Instrument size 100mm diameter x 275mm long
Carrying case size 450mm x 340mm x 220mm
3.2 BCM Charger
Supply Voltage:- 110V to 240V A.C. 45-55 Hz
Input Power :- 3.5 VA maximum
Output voltage :- 10.5V D.C. open circuit.
Output Current :- 30mA ± 2mA
Charging indicator :- Green LED