Page 54
2. High fuel consumption
3. Backpuffing
4. Smoke rollout when heater
door is opened
1. (a) Close inlet air control
as much as possible to
maintain desired heat
output.
(b) Check gaskets,
reinstall fiberglass
gasketing round doors
and glass as necessary
2. Check door gasket,
check adjustment of door
latch
1. Chimney may need wind
divider. Raise chimney
for better draft.
1. Chimney may need
wind diverter. Raise
chimney for better draft.
2. Crack door for 15
seconds before fully
opening door.
1. Improper regulation of
draft or inlet air
2. Improper door fitting
1. Gusts of Wind
1. Wind gusts blowing down
the chimney
2. Opening heater door too
fast
PROBLEM POSSIBLE CAUSE SOLUTION