17
TIM ADJ
0
Clock
The time clock can be adjusted if the clock runs too fast
or too slow with the ‘TIM ADJ”.
For example: If the clock runs 10 seconds too fast per day,
set the TIME ADJ to -10.
Range is -59 to +59 sec/day.
To change the “TIM ADJ”:
1. Enter the key code.
2. Press the “INS button repeatedly until ‘TIM ADJ”
appears in the display.
3. Turn the knob until the desired time
adjustment appears in the display.
Automatic operation is resumed after 20 seconds.
Installation Entries 4
4 Installation Entries
16
FLUE GAS
OFF
Flue Gas
The flue gas temperature can only be measured with an
additional module, not available in the United States.
The factory setting is “OFF”. This must remain in the off
position or an error message will appear.