Electrical Wiring
DW464 and DW467
DW464 and DW467 are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp
fuse as standard.
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any
emergency disconnection being required they must be readily accessible.
DW468
DW468 Must be installed by a qualified electrician
DW468 is supplied wired for installation to a single
phase 230v 30A power supply.
DW468 can also be rewired by a qualified electrician to work on a single phase 230v 13A
supply (Power reduced to 26600w) or three phase 400v 12.2A power supply.