EasyManua.ls Logo

Bühler technologies Nivotemp NT-M Series - 9 Appendices; Technical Data NT-M

Bühler technologies Nivotemp NT-M Series
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Nivotemp NT-M
9 Appendices
9.1 Technical Data NT-M
Version MS VA Dimensions
Operating pressure: max. 1 bar * max. 1 bar
L1 = min. 40
L = 280 / 370 / 500 / max. 1000
L2 = min. 80
min. 50
59
G3/4 = SW 36
G1 = SW 41
3.5
* min. 80 with
2x temp. contact
G3/4 /
G1
Ø23.5
last contact
first contact
45
G3/4 = 16
G1 = 18
Ø4.5
2
~ 37
45
5
8
Ø52
43
Ø38
55
80
Ø55
Ø6.5
R13
Flange style
Oval flange
(NBR
seal)
Operating temperature: -20 °C to +80 °C -20 °C to +80 °C
Float: SK 161 SK 161
Min. fluid density: 0.80 kg/dm³ 0.80 kg/dm³
Lengths (all versions): 280, 370, 500 mm (standard)
variable to max. 1000 mm
Weight at L=500 mm: approx. 300 g approx. 350 g
* max. atmospheric for PA oval flange
Material
Float: NBR NBR
Immersion tube: Brass 1.4571
G3/4 connection: Brass 1.4571
G1 connection: Brass Brass
via adapter
Flange connection: Aluminium --
Oval flange: PA VA/brass
via adapter
Level switching output K8 W9
Max. number 4 2
Function: NO/NC* Change-over contact
Max. voltage: 230 V DC/V AC 48 V AC/V DC
Max. switching current: 0.5 A 0.5 A
Max. contact load: 10 VA 20 VA
Min. contact spacing: 40 mm 40 mm
*NO= falling NC contact / NC = falling NO contact
Optional temperature
Temperature contact: TM xx
Max. voltage: 230 V DC
Max. switching current: 2 A
Max. contact load: 100 VA
Function: NC NO
Switching point °C: 50/60/70/80 50/60/70/80
Switching point tolerance: ± 5 K ± 5 K
Max. hysteresis: 18 K ± 5 K 26/35/40/45 K ± 5 K
Temperature sensor
Pt100: DIN EN 60 751 (tolerance ± 0.8 °C)
Analogue output: See "Technical Data NT-M with Analogue
Output for Temperature"
Adapter
OV: Adapter to oval flange incl. seal and locking
nut
G1: Adapter G3/4 to G1
14 Bühler Technologies GmbH BE100021 ◦ 03/2017