Float: NBR
Immersion tube: Brass
G3/4 connection: Brass
Level switching output K8
Max. number: 2
Function: NO/NC*
Max. voltage: 30 V DC
Max. switching current: 0.5 A
Max. contact load: 10 VA
Min. contact spacing: 40 mm
*NO= falling NC contact / NC = falling NO contact
Optional temperature
Temperature KT
Detector: PT100 Class B, DIN EN 60 751
Measuring range*: 0 °C to 100 °C
Operating voltage (UB): 10-30 V DC
Outlet: 4-20 mA
Max. burden Ω: = (UB-7.5 V)/0.02 A
*Other measuring ranges available upon request
Adapter
OV: Adapter to oval flange incl. seal and
locking nut
G1: Adapter G3/4 to G1
9.5 Connector NT-M with analogue output for temperature
Connector M12 2 x M12
Number of pins 4-pin 2 x 4-pin
DIN EN 61076-2-101 175201-804
Connection schematic
1 x level contact
and analogue output
2 x level contact
and analogue output
17Bühler Technologies GmbHBE100021 ◦ 03/2017