Hardware Setup/Wiring Diagram BFBP21S (50 Hz STIL Model)
Template 40981_C 02-17-10
56708_97_A 01-23-15
4
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2009 Balboa Water Group.
Wiring Diagram
Hardware Setup
01-23-15
BFBP21S – PN 56708
PUMP 2 IS USED IN SETUPS 1 & 2 ONLY
J25 J31
J26 J30
115V 115V
230V
F3 0.125A 240V
J25=HTR1
J26=HTR2
J27=HTR3
J30=TEST
J31=CE
HTR
SEL
F7 10A 250VAC
F2 10A 250VAC
J44
3
TB1
J15
ON
10
S1
K5
K1
K3
T1
K2
K4
K8
UNUSED
GND
J33
J21
J32
J9
1
2
3
4
2
K6
Print Offsets:
+10 Top
+0020 Left
4
3
2
1
J45
J110
J79
J54
J72
J42
J3
J37
J4
J1
J61J47
J77
J75
J78
J36
J60
J46
J38
J39
J111
J53 J58
J11
J41
J48
J6
J7
J49
J19
J50
J13
J12
J88
J62
F6 30A
F8 30A
J56
J57
J55
J59
J51
J52
J98
J10
J81
J20
J18
J43
CIRC PUMP
UNUSED
A/V HOT
PUMP 1
J14
PUMP 2
K9
J5
AUX
J8
AUX
J40
REMOTE
J35
MAIN
J34
MAIN
J109
J27
J91
J22
J23
SERIAL
J28
AUX
FRZ
J17 J16
J101
J108
J24
J107
K12
K7
TP (MAIN) PANELS
J34 OR J35
PART A
F4 3A SLO-BLOW
2.5HP (10.3A MAX) PUMPS REQUIRE 1þ / 3x16A
SERVICE WHEN SYSTEM IS CONFIGURED IN SETUP 1 OR 2.
J29
VAC
HTR
DISBL
AUX
J5 (A1-A4)
OR
J8 (A5-A8)
GRN
BLU
BRN
230V
1x32A
230V
1x16A
SETUPS 3 & 4
ONLY
SENSOR B
SENSOR A
3.0 kW HEATER
SPLITTER
LOCATION DEVICE VOLTS AMPS FROM TO FROM TO
J1 ON OZONE+EXT 230V 2A W1 ON GROUP 2 J6 ON GROUP 3
EXPANDER LIGHTING MAX EXPANDER J1 EXPANDER J58
J1
W1
J7
RIGHT
EXPANDER
BOARD
J6
EXPANDER
X-P332
F1 30A
WiFi
Transceiver
J34 OR J35
IR Receiver
OR
RF Receiver
FOR SUPPLY CONNECTIONS,
USE CONDUCTORS SIZED ON THE
BASIS OF 60°C AMPACITY BUT
RATED MINIMUM OF 90°C.
TORQUE RANGE FOR
MAIN TERMINAL BLOCK (TB1):
27-30 IN. LBS.
(31.1-34.5 kg cm)
USE COPPER CONDUCTORS ONLY.
EMPLOYER UNIQUEMENT
DES CONDUCTEURS DE CUIVRE.
SYSTEM WILL BE SHIPPED IN SETUP #2
UNLESS MARKED OTHERWISE
INSTEAD OF SETUP #2,
THIS SYSTEM IS
CONFIGURED IN SETUP #:
Settings
Template 40981_C 02-17-10
56708_97_A 01-23-15
5
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2009 Balboa Water Group.
Settings
Hardware Setup
PART B
BASED ON BP2500 STICKER KIT TEMPLATE UPDATED 02-17-10
PART B
BFBP21S – PN 56708
01-23-15
LOCATION DEVICE
J9 NETZSTROMVERSORGUNG 2-GESCHW.-PUMPE 1 ALIMENTATION POMPE 1 A 2 VITESSES 2-SPEED PUMP 1
J14 NETZSTROMVERSORGUNG 2-GESCHW.-PUMPE 2 ALIMENTATION POMPE 2 A 2 VITESSES 2-SPEED PUMP 2
PUMP 2 LINE 1 CONNECTION J19 to J43
J21 KREISLAUF PUMPE POMPE DE CIRCULATION CIRC PUMP
CIRC AND OZONE LINE 1 CONNECTION J81 to J59
J32 N/A
J33 TV / AV
J40 IR RECIEVER
J5, J8 AUX PANEL(S) - AX10, AX20, AX30, AX40
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
SWITCHBANK S1 OFF SWITCHBANK S1 ON
CIRC PUMP OPTION
PROGRAMMABLE FILTRATION CYCLES +
POLLING
USED IN SETUPS 1 & 3
SINGLE SERVICE 230V 1þ / 1x32A, TWO-SERVICE 230V 1þ / 2x16A, THREE-SERVICE 230V 1þ / 3x16A
230V 1þ
1x32A
230V 2þ
2x16A
230V 3þ
3x16A
TEST MODE OFF
DON’T ADD 1 HS PUMP W/HTR
DON’T ADD 2 HS PUMPS W/HTR
DON’T ADD 4 HS PUMPS W/HTR
SPECIAL AMPERAGE RULE A
STORE SETTINGS**
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
TEST MODE ON
ADD 1 HS PUMP WITH HEAT
ADD 2 HS PUMPS WITH HEAT
ADD 4 HS PUMPS WITH HEAT
SPECIAL AMPERAGE RULE B
MEMORY RESET**
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
**SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION.
1* PROGRAMMABLE FILTRATION + POLLING 2-SPEED 2-SPEED °C
2* 2-SPEED 2-SPEED °C
3 PROGRAMMABLE FILTRATION + POLLING 2-SPEED °C
4 2-SPEED °C
SETUP # CIRC PUMP PUMP 1 PUMP 2 TEMP SCALE
SYSTEM WILL BE IN
SETUP #2
UNLESS MARKED
DIFFERENTLY
BELOW
PUMP 1 LOW TIMEOUT IS 60 MINUTES.
230V 1þ 1X16A
A2
A3
A4
OFF ON
230V 2þ / 2x16A
GRN
1 BLU
2 BRN
1 BRN
2 BLU
TB1
1
2
3
4
4
3
2
1
J78
J45
J79
J72
J42
J3
J37
J4
J1
J61J47
J54
J77
J75
J36
J60
J53 J58
J41
J12
J88
J62
J51
J52
J98
J18
J38
J3
J20
J46
W12
X-B
EXPANDER
J81
230V 3þ / 3x16A
GRN
BLU
1 BRN
2 BRN
3 BRN
* 2.5HP (10.3A MAX) PUMPS REQUIRE
1þ / 3x16A SERVICE WHEN SYSTEM IS
CONFIGURED IN SETUP 1 OR 2.
TB1
1
2
3
4
4
3
2
1
J78
J45
J79
J72
J42
J3
J37
J4
J1
J61J47
J54
J77
J75
J36
J60
J53 J58
J41
J12
J88
J62
J51
J52
J98
J38
J18
J46
J3
J20
W12
X-B
EXPANDER
J81
TO
J1 ON
EXPANDER
OZONE
EXT. LIGHTING
TO (GROUP 2)
ON MAIN BOARD
WHITE
RED
WHITE
GREEN
GREEN
BLACK
LOCATION DEVICE VOLTS MAX AMPS
J1 ON OZONE 230V 1A USING SPLITTER
EXPANDER + EXT.
BOARD XP332 LIGHTING
Template 40981_C 02-17-10
56454_97_A 01-24-13
4
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2009 Balboa Water Group.
Wiring Diagram
Hardware Setup
01- 24- 13
PUMP 2 I S USED I N
SETUP 1 ONLY
F4 1/ 2A SLO- BLOW
J25 J31
J26 J30
120V 120V
240V
F3 0. 3A SLO- BLOW
J 25=HT R1
J 26=HT R2
J 27=HT R3
J 30= TEST
J31=CE
HTR
SEL
F7 10A 250VAC
F2 10A 250VAC
J44
3
TB1
J15
ON
10
S1
K5
K1
K3
T1
K2
K4
K8
L I GHT
GND
J33
J21
J32
J9
1
2
3
4
2
4
3
2
1
J45
J110
J79
J54
J72
J42
J3
J37
J4
J61
J77
J75
J78
J36
J46
J38
J39
J111
J11
J48
J6
J7
J49
J19
J13
J12
J88
J62
F6 30A
J56
J57
J55
J59
J51
J52
J98
J81
J20
J18
UNUSED
OZ ONE
A/ V HOT
PUMP 1
J14
PUMP 2
K9
J5
AUX
J35
MA I N
J34
MA I N
J109
J27
J91
J22
J23
SERI AL
J29
VAC
J28
AUX
FRZ
J17 J16
24082_D
J108
J24
K12
K7
TP ( MAI N) PANELS
J34 OR J35
PART A
OPTI ONAL 1 2 0 VAC CONF I GURATI ON FOR SETUP 2 ONL Y:
TRANSFORMER J UMPERS
WHEN HEATER I S 120 V
TB1
1
2
3
4
J78
J45
J79
J72
J42
J3
J37
J4
J61
J54
J77
J75
J36
J12
J88
J62
J51
J52
J98
4
3
2
1
GRN
BLK
WH T
GF CI
120V 120V
240V
J24
A3*
* SWI TCH # 3 SHOUL D BE SET T O OFF WHEN
SETUP 2 I S CONFI GURED AS 120 VAC.
AUX
J5 ( A1- A4)
GRN
WH T
RED
BLK
BFBP20GX – PN 56454
SENSOR B
SENSOR A
4. 0 k W HEATER
CABI NET
L ED L I GHT
1 2 VAC ( HOT )