Spa pump will not turn on, creates a burning smell while running, or makes
excessive noise while running:
Cause: Pump motor is defective. Running during high ambient outside
temperatures, Excessive run time
Solution: Contact your authorized Bullfrog Spas Dealer.
Jets are weaker than normal or do not work at all, but the pump is running:
Cause #1: Jet handle(s) Swim Spa JetPak I are partially or fully closed. Valves
are closed Series A & R JetPak II,
Solution: Open jet handle(s) / valve(s).
Cause #2: Filter cartridge is dirty.
Solution: See Cleaning the Filter.
Cause #3: ere is air trapped in the spa equipment or its face piping.
Solution: Remove the clamp to the air bleed line and remove the air line
from the pump until air has purged out and you see water ow and recon-
nect.
Cause #4: e suction tting(s) are blocked.
Solution: Remove any debris that may be blocking the suction tting(s).