DIAGNOSTICS
Intermittent flashing of the READY indicator (Model CEZ) or the bank of temperature indicators (Model CDBC)
indicates that a fault exists. Count the number of flashes between pauses and use this chart as a guide to
investigating the fault.
FLASHES CAUSE THINGS TO CHECK
1 Dry Plug - In Fault - Water Pressure
Sheath of temperature probe dry for 10 minutes after power-up Temperature probe wiring
Fill valve wiring, function, & strainer
Green wire between tank and circuit board
2 Low Tank Level Fault - Water pressure
Level probe dry for 7 minutes after fill valve is energized Level probe wiring
Temperature probe wiring
Fill valve wiring, function, & strainer
3 Low Water Temperature Fault - Tank heater wiring & function
Sensor in tank is calling for heat for 30 minutes or more Temperature probe wiring
4 Tank Sensor Disagreement - Temperature probe wiring
Level probe detects water, but dry plug-in probe dry Level probe wiring
Green wire between tank and circuit board
5 Temp Sensor Out-of-Range - High Sensor not connected to circuit board
6 Temp Sensor Out-of-Range - Low Sensor wires shorted together or to chassis