5
ELECTRICAL REQUIREMENTS
WARNING - The dispenser must be disconnected from the power source until specified in Initial Set-Up.
Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements.
208 & 240 volt ac models
Note: This electrical service consists
of 2 current carrying conductors (L1
and L2) and a separate conductor for
earth ground.
230 volt ac models
Note: This electrical service con-
sists of 2 current carrying conduc-
tors (L1 and Neutral) and a separate
conductor for earth ground.
120 volt ac models
Note: This electrical service con-
sists of 2 current carrying conduc-
tors (L1 and Neutral) and a separate
conductor for earth ground.
Electrical Hook-Up
CAUTION – Improper electrical installation will damage electronic com-
ponents.
1. An electrician must provide electrical service as specified.
2. Using a voltmeter, check the voltage and color coding of each conductor
at the electrical source.
3. Turn off master switch (if equipped).
4. Remove the upper and lower rear panels.
5. Install the proper electrical wiring to the terminal block.
6. Connect the dispenser to the power source and verify the voltage at
the terminal block before proceeding. Reinstall both rear panels.
7. If plumbing is to be hooked-up later be sure the dispenser is discon-
nected from the power source. If Plumbing has been hooked-up, the
dispenser is ready for Initial Set-Up.
CE REQUIREMENTS
• This appliance must be installed in locations where it can be overseen
by trained personnel.
• For proper operation, this appliance must be installed where the tem-
perature is between 5°C to 35°C.
• Appliance shall not be tilted more than 10° for safe operation.
• An electrician must provide electrical service as specied in confor-
mance with all local and national codes.
• This appliance must not be cleaned by water jet.
• This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given instructions concerning use
of this appliance by a person responsible for its safety.
• Children should be supervised to ensure they do not play with the
appliance.
• If the power cord is ever damaged, it must be replaced by the manu-
facturer or authorized service personnel with a special cord available
from the manufacturer or its authorized service personnel in order to
avoid a hazard.
• Machine must not be immersed for cleaning.
46819 043012
120/208 & 120/240V ac
single phase models
Note: This electrical service consists
of 3 current carrying conductors
(Neutral, L1 and L2) and a separate
conductor for earth ground.
DUAL VOLT TOGGLE SWITCH