EasyManuals Logo

Bunn SINGLE SH DBC Operating Manual

Bunn SINGLE SH DBC
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
Page 39
34025 100501
Equipment will not operate.
Brew cycle will not start.
Automatic refill will not operate or
display shows FILL TIME TOO LONG
1. No power or incorrect voltage.
1. No water
2. ON/OFF switch
3. Brew switch
4. Brew Valve
5. Electronic Control Board
1. No water
2. Water strainer/flow control
(.750 GPM)
Measure the voltage at the terminal
block and confirm that it matches
the voltage specified on the brewer
data plate within +/- 10%.
Check plumbing and shut-off valves
Test the ON/OFF switch. Refer to the
switch test procedures on page 32.
Test the BREW switch. Refer to the
switch test procedures on page 32.
Test the Brew valve. Refer to
Testing
Individual Components
on page 32.
Substitute a control board known to
be in good working order.
Check plumbing and shut-off valves.
(A) Direction of flow arrow must be
pointing towards direction of water
flow.
(B) Remove the strainer/flow con-
trol and check for obstructions. Clear
or replace.
TROUBLESHOOTING (cont.)
Troubleshooting Procedure
Problem
Possible Cause

Other manuals for Bunn SINGLE SH DBC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bunn SINGLE SH DBC and is the answer not in the manual?

Bunn SINGLE SH DBC Specifications

General IconGeneral
BrandBunn
ModelSINGLE SH DBC
CategoryCoffee Maker
LanguageEnglish

Related product manuals