EasyManua.ls Logo

Bunn SINGLE SH DBC - Troubleshooting - Beverage Volume and Filter; Beverage Volume and Filter-Related Issues

Bunn SINGLE SH DBC
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 45
34025 100501
TROUBLESHOOTING (cont.)
Problem
Possible Cause Troubleshooting Procedures
Weak beverage (cont.)
Brewer is making unusual noises.
6. Incorrect Recipe
1. Solenoid (Inlet)
2. Plumbing lines
3. Water Supply
4. Tank Heaters.
Consider adjusting bypass percent-
age, preinfusion, or pulse brew.
Contact Bunn-O-Matic for sugges-
tions.
The nut on back of the solenoid
must be tight or it will vibrate during
operation
Plumbing lines should not be rest-
ing on the counter top.
(A) The brewer must be connected
to a cold water line.
(B) Water pressure to the brewer
must not be higher than 90 psi (620
kPa). Install a regulator if necessary
to lower the working pressure to
approximately 50 psi (345 kPa).
Remove and clean lime off tank heat-
ers.

Other manuals for Bunn SINGLE SH DBC

Related product manuals