INITIAL SET-UP
CAUTION - The brewer must be disconnected from the power source throughout the initial set-up, except when
specifi ed in the instructions.
1. Remove the top lid from the brewer.
2. Rotate the control thermostat knob fully counterclockwise to the "OFF" position and replace the top lid.
3. Set the delay knob of the timer on the right side of the hood at eight minutes and the dilution knob of the
timer on the right side of the hood at three minutes and forty-fi ve seconds.
4. Remove the metal discharge tip from the funnel to speed up the set-up procedure. Insert the empty funnel
into the funnel rails.
5. Place an empty dispenser on the brewer base. Be sure the funnel discharge is directly above the hole in the
dispenser top lid.
6. Plug in the brewer and place the ON/OFF switch in the "ON" position. Momentarily press the start switch.
Water will fl ow into the tank and will shut off after three minutes. Press the start switch again. During the
second period, the tank will fi ll to its capacity and the excess will fl ow from the funnel into the dispenser.
7. Place the ON/OFF switch in the "OFF" position.
8. Disconnect the brewer from the power source and remove the top lid.
37235 050205
oo
oo
9. Rotate the control thermostat knob fully clockwise to
the "ON" position and replace the top lid.
10. Plug in the brewer and wait for the water in the tank
to heat to the proper temperature (approximately 20
minutes). Some water will drip from the funnel during
this time; this is due to expansion and should not occur
thereafter.
11. Place an empty dispenser under the funnel.
12. Place the ON/OFF switch in the "ON" position and press
the start switch. Empty the dispenser after water has
stopped fl owing from the funnel.
13. Allow the water in the tank to reheat to the proper
temperature.
14. Place the ON/OFF switch in the "ON" position and press
the start switch.
15. Place the ON/OFF switch in the "OFF" position im-
mediately after water stops fl owing from the funnel.
Check the water volume in the dispenser. It should be
seventy-six ounces.
16. If not, unplug the brewer, remove the top lid, and adjust
the timer on the left side of the hood as required. See
Adjusting Brew Volumes. Replace the top lid, plug in
the brewer, start, and measure another concentrate
cycle.
17. Repeat steps 13-16 until the proper water volume is achieved.
18. Unplug the brewer and remove the top lid.
19. Set the delay knob of the timer on the right side of the hood at three minutes and empty the dispenser.
20. Place the ON/OFF switch in the "ON" position, momentarily press the start switch, and allow both the con-
centrate and dilution cycles to occur.