EasyManuals Logo

Bunn TB6Q User Manual

Bunn TB6Q
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Page 8
AUTO SWEETENER SET-UP
CAUTION - The brewer must be disconnected from the power source throughout the Initial Set-Up, except
when specified in the instructions.
1. Remove the top lid and both rear panels.
2. Make sure the brewer water supply is off.
3. Connect sweetener hose from the bag in a box delivery system to the rear fitting marked "Sweetener" .
IMPORTANT - System delivery pressure must be regulated between 30-40 psi. System also needs to deliver
product for at least 4 minutes without shutting off. Some pump systems shut off after a few minutes of con-
tinuous running.
(TB3Q/TB3Q-LP ONLY)
4. Plug brewer into the power source.
5. Place an empty reservoir under the dilution nozzle of the brewer.
6. Close the adjustment valve on the rear of the brewer fully (clockwise), then open (counterclockwise)
1/2 turn.
7. Set the selector switch to the "Sweetened" side and press the "Start" switch momentarily. (The sweet-
ener will come out immediately.)
8. Run sweetener for 1 minute, then set selector switch to the "Off" position. The flow will stop.
9. Measure the amount of sweetener dispensed and calculate if the volume needs to be increased or
decreased (Dilution cycle is usually between 3 to 3 1/2 minutes).
10. If adjustment is needed, turning the adjustment valve clockwise decreases the amount of sweetener
dispensed and turning the adjustment valve counterclockwise increases the amount of sweetener dispensed.
11. After the desired volume has been set, turn the water supply on.
12. Reinstall the top lid and rear panels. The brewer may now be returned to service.
(TB3/TB3-LP ONLY)
4. Set the "Delay knob on the dilution timer to the 3 minute setting. (The minimum delay setting)
5. Plug brewer into the power source.
6. Place an empty reservoir under the dilution nozzle of the brewer.
7. Close the adjustment valve on the rear of the brewer fully (clockwise), then open (counterclockwise) 1/2
turn.
8. Set the selector switch to the "Sweetened" side and press the "Start" switch momentarily. (After approximately
3 minutes the sweetener will come out of the dilution nozzle.)
9. Run sweetener for 1 minute, then set selector switch to the "Off" position. The flow will stop.
10. Measure the amount of sweetener dispensed and calculate if the volume needs to be increased or decreased
(Dilution cycle is usually between 3 to 3 1/2 minutes).
11. If adjustment is needed, turning the adjustment valve clockwise decreases the amount of sweetener dis-
pensed and turning the adjustment valve counterclockwise increases the amount of sweetener dispensed.
12. Set the "Delay" knob on the dilution timer back to the 6 to 7 minute setting.
13. After the desired volume has been set, turn the water supply on.
14. Reinstall the top lid and rear panel. The brewer may now be returned to service.
41465.1 082208

Other manuals for Bunn TB6Q

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bunn TB6Q and is the answer not in the manual?

Bunn TB6Q Specifications

General IconGeneral
BrandBunn
ModelTB6Q
CategoryKitchen Appliances
LanguageEnglish

Related product manuals