8 08/54070/0 (Issue 5)
7.0 Burco boiler Installation
7.1 Before connecting to the power supply
Remove all packaging and plastic coating from the appliance.
Check the unit has not been damaged in any way during transportation. Report any damage to the
company who sold you the boiler right away.
Check the available power supply corresponds to that shown on the rating label of the appliance,
which must be A.C. (Alternating Current).
Ensure the yellow steam cap is removed from the steam vent prior to powering appliance.
The location must be frost free.
7.2 Connecting to the water supply
Connection from the cold-water supply to the appliance should only be made by the hose supplied.
In hard water areas, it is always advisable to fit an inline filtration unit to limit scale build-up. If you
have purchased a Burco boiler that does not have a water filter system included, we recommend
you fit a separate water filter between the boiler and the mains
supply.
Always ensure mains water supply is turned off, or localised
isolation valves are closed before attempting to connect boiler
to the mains water supply.
The inlet water connection to the inlet solenoid valve is ¾” BSP,
this should be connected to the mains water supply via an
accessible isolating tap.
The blue pipe connects to the grey fitting which can be found underneath the appliance.
Firmly push the blue pipe into the small outlet hole on the grey fitting.
Ensure grey connection is screwed tight on the appliance and not leaking.
Locate the second grey connection fitting. Connect the other end of the blue pipe to this. This
second grey connection fitting is connected to the mains water supply forming a cold-water feed
from the mains water supply to the Burco boiler.
Do not use old water hose.
THIS APPLIANCE MUST BE INSTALLED IN LOCATIONS OVERSEEN BY TRAINED PERSONNEL & ON A
FLAT, HORIZONTAL SURFACE.