EasyManua.ls Logo

Burley G4121 User Manual

Burley G4121
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
G4121 AMBIENCE
FLUELESS GAS APPLIANCE
INSTALLATION, SERVICING
& USER INSTRUCTIONS
FOR USE IN THE COUNTRIES STATED ON THE DATA PLATE AND CARTON
WITH NATURAL GAS G20
OR PROPANE GAS G31
(REFER TO RATING LABEL)
For the following countries: GB, IE
EVEN IF YOU HAVE FITTED THESE FIRES BEFORE,
PLEASE FOLLOW THESE INSTRUCTIONS STEP BY STEP.
Legislation and regulations do change over time!
This product is not suitable for primary heating purposes.
LEAVE THESE INSTRUCTIONS WITH THE USER
Burley Appliances Ltd,
Lands End Way, Oakham, Rutland, LE15 6RB
Telephone: +44 (0)1572 756956 Fax: +44 (0)1572 724390
e-mail:
info@burley.co.uk web: www.burley.co.uk
G4121InstUser
G20/31
March 2018
THE INSTALLER AND CUSTOMER MUST FILL IN THE SEPARATE GUARANTEE
AND RETURN IT TO BURLEY WITIHIN 7 DAYS OF FITTING.
A FREE SECOND YEAR GUARANTEE IS OFFERED SUBJECT TO THE FIRE BEING SERVICED
BY A GAS SAFE™ REGISTERED ENGINEER (FORMERLY CORGI) DURING THE FIRST YEAR OF OWNERSHIP.
PROOF OF SERVICING MUST BE RETAINED
FAILURE TO HAVE THIS APPLIANCE FITTED BY A GAS SAFE ™ REGISTERED
INSTALLER (FORMERLY CORGI)
INVALIDATES THE WARRANTY
Question and Answer IconNeed help?

Do you have a question about the Burley G4121 and is the answer not in the manual?

Burley G4121 Specifications

General IconGeneral
BrandBurley
ModelG4121
CategoryGas Heater
LanguageEnglish

Summary

Lighting Procedure

Total Control Setup

Ensures ON/OFF switch and manual knob are correctly set for lighting.

Manual Control Operation

Lighting the Fire

Step-by-step guide to lighting the pilot and main burner.

General Requirements and Safety

Installation and Regulatory Compliance

Details legal installation requirements, regulations, and standards.

Ventilation and Room Size

Specifies room volume, ventilation, and vent placement rules.

Appliance Placement and Clearances

Outlines safe distances from furnishings, walls, and openings.

Prohibited Installation and Usage

Lists unsafe locations and usage restrictions for the appliance.

Warnings and Floor Protection

General Safety Warnings

Important safety advice for using the appliance.

Installation Clearances and Gas Supply

Installation Clearances

Specifies minimum distances to walls and shelves around the appliance.

Gas Supply Connection

Details gas connection, pipework, and isolator requirements.

Siting and Room Requirements

Covers flue blocking, fan siting, room checks, and ventilation.

Installation Preparation and Testing

Includes data plate check, positioning, and gas leak testing.

Commissioning and Troubleshooting

Inlet Pressure and Adjustment

Verifying and adjusting inlet gas pressure as per specifications.

Oxygen Depletion Pilot System

Details of the ODS safety feature and its maintenance requirements.

Servicing Instructions and Checks

Annual Servicing Procedures

Detailed steps for annual maintenance, combustion analysis, and checks.

Flue Gas Analysers and Catalytic Convertor

Testing Procedures

Details CO/CO2 ratio test and room centre CO test requirements.

Gas Rating and Tolerances

Installer Tolerances and Measurement

Guidance for installers on gas rate testing and pressure.

Domestic Guarantee Conditions

Guarantee Conditions

Lists requirements for installation, room size, venting, and servicing.