What to do if BUSCH Air Compressor doesn't reach usual pressure?
- MMatthew AvilaSep 12, 2025
If your BUSCH Air Compressor isn't reaching its usual pressure, several factors could be at play. Check if the inlet screen is partially clogged and clean it if necessary. Similarly, the inlet filter cartridge might be clogged and require replacement. Ensure the pressure system connection is leak-tight by inspecting the hose or pipe connections. The pressure relief valve might also be improperly adjusted or defective, requiring adjustment, repair, or replacement. A clogging in the discharge line can also be the cause, so remove the clogging. If none of these steps resolve the issue, the internal parts may be worn or damaged, requiring you to repair the machine (contact Busch).