EasyManua.ls Logo

BUSCH SV 1040 C - User Manual

BUSCH SV 1040 C
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Get technical data,
instruction manuals,
service kits
Instruction Manual
SECO
Dry-running Rotary Vane Vacuum Pumps
SV 1010 C, SV 1016 C, SV 1025 C, SV 1040 C
SD 1010 C, SD 1016 C, SD 1025 C, SD 1040 C
DC 0025 C, DC 0040 C
0870569132/-0005_en / Original instructions / Modifications reserved 21/04/2021
Busch Vyroba CZ s.r.o.
Svárovská 620, CZ 460 01, Liberec 11
Czech Republic

Questions and Answers

  • K
    Kim MillsAug 9, 2025
    Why does my BUSCH Water Pump run too hot?
    • C
      Christina HarrisAug 9, 2025
      Your BUSCH Water Pump might be running too hot due to several reasons: insufficient cooling, which can be resolved by removing dust and dirt from the machine; ambient temperature being too high, so observe the permitted ambient temperature; the internal filters (IIF, IDF) are partially clogged, so replace the filter cartridge; or the inlet filter (optional) is partially clogged, so replace the filter cartridge.
  • C
    Corey KimAug 19, 2025
    Why does my BUSCH Water Pump not reach the usual pressure?
    • T
      thughesAug 20, 2025
      There are several potential causes for a BUSCH Water Pump not reaching its usual pressure. The internal filters (IIF, IDF) or the inlet filter cartridge (optional) might be partially clogged, so replace the filter cartridge. One of the regulating valves (VRV, PRV) could be jammed in an open position, so it should be dismantled, cleaned, checked and reassembled. Alternatively, the vanes could be stuck, so free them or replace them. Also the vanes (VA) might be worn, so replace the vanes. Finally, the felt washer of the discharge valve (DV) might be partially clogged (SV version only), so dismantle the discharge valve and change the felt washer.
  • E
    Elizabeth WilliamsAug 29, 2025
    What to do if my BUSCH Water Pump runs very noisily?
    • W
      wheelerstephenAug 29, 2025
      If your BUSCH Water Pump is running very noisily, it could be due to the machine running in the wrong direction, so check the direction of rotation. It also might be caused by defective bearings.

Summary

Safety

Installation

Electrical Connection

Covers safety precautions and requirements for electrical hookup.

Commissioning

Maintenance

Maintenance Schedule

Outlines recommended maintenance intervals and tasks for different vane types.

Change Vanes and Internal Filters

Step-by-step guide for replacing vanes and internal filters.

Check Vane Height

Details how to check vane height and when replacement is needed.

Troubleshooting

Technical Data

BUSCH SV 1040 C Specifications

General IconGeneral
BrandBUSCH
ModelSV 1040 C
CategoryWater Pump
LanguageEnglish

Related product manuals