GasAlertClip Extreme English Instruction Sheet
D2139/5 Page 1
Trimmed and folded dimensions: 4.125 (w) x 5.875 (h)
BW TECHNOLOGIES
GasAlertClip Extreme
2 or 3 Year Gas Detector
Instruction Sheet
Introduction
The GasAlertClip Extreme gas detector (the detector) is a personal safety
device that warns when hazardous gas exceeds factory set alarm setpoints.
The detector stores and transmits gas alarm event data. It is your
responsibility to respond properly to the alarms.
Gas Detected Unit of Measure
Oxygen (O
2
) Percent by volume (%)
Carbon monoxide (CO) Parts per million (ppm)
Hydrogen sulfide (H
2
S) Parts per million (ppm)
Sulfur dioxide (SO
2
) Parts per million (ppm)
a Safety Information - Read First
Warning: Substitution of components may impair Intrinsic Safety.
Warning: To prevent ignition of flammable or combustible
atmospheres, disconnect power before servicing.
Do not activate the detector after the date on the package.
This product is a gas detector, not a measurement device.
Perform a self-test each day prior to use.
Ensure the sensor grill is free of dirt and debris.
Ensure the sensor grill is not obstructed.
Periodically test the response of the sensor to gas by exposing the
detector to a target gas concentration that exceeds the low alarm
setpoint. Manually verify that the audible and visual alarms are
activated.
Periodically calibrate the GasAlertClip Extreme O
2
.
D2139/5 (English)
iERP: 119566
© 2005 BW Technologies LP. All rights reserved. Printed in Canada
ec Note:
This instrument contains a lithium battery. Do not mix with the solid
waste stream. Spent batteries should be disposed of by a qualified
recycler or hazardous materials handler.
Parts of the GasAlertClip Extreme
1 Audible alarm
2 Visual alarm
3 Infrared download port
4 Liquid crystal display (LCD)
5 Alligator clip
6 Start/test button
7 Sensor and sensor grill
Display Elements
1 Maximum exposure in alarm
2 Data transmission
3 High and low alarm setpoints
4 Self-test status
5 Gas type
3 / 6 Alarm condition
7 / 8 Detector life-remaining indicators
1 / 8 Months/hours/days since last maximum exposure
Pushbutton
Pushbutton Description
C
To activate the detector, press and hold C for 5
seconds.
Press C within 24 hours of receiving a gas alarm
to view the maximum gas exposure.
When Test displays, press and hold
C for
approximately 1 second to activate the self-test.
To calibrate the O
2
detector,
press and hold C
for approximately 3 seconds.
To display the gas alarm setpoints, press C.
To transmit the data, press C when Prn and
display.
Question and Answer IconNeed help?

Do you have a question about the BW Technologies GasAlertClip Extreme and is the answer not in the manual?

BW Technologies GasAlertClip Extreme Specifications

General IconGeneral
BrandBW Technologies
ModelGasAlertClip Extreme
CategoryGas Detectors
LanguageEnglish

Summary

Device Overview and Components

Introduction to GasAlertClip Extreme

Basic overview of the detector's function and user responsibility.

Physical Components

Identifies and illustrates the physical parts of the detector, including casing and sensors.

Display Elements

Details the various indicators and icons shown on the detector's LCD screen.

Pushbutton Functions

Explains the operations and functions associated with the detector's pushbuttons.

Critical Safety Information

Outlines essential safety warnings and mandatory precautions for safe operation.

Detector Operation and Safety

Activating and Daily Self-Test

Guides on detector activation and the mandatory daily self-test procedure.

Automatic Battery and Safety Shutdown

Explains automatic battery tests and conditions for entering safety shutdown mode.

Detector Life-Remaining Clock

Details how the device indicates its remaining operational lifespan in months, days, and hours.

Gas Alarm Setpoints

Lists the predefined alarm thresholds for various gases and how to display them.

Alarm Behavior and Exposure Monitoring

Alarm Notifications

Details the audible, visual, and vibration alerts for low, high, and life-ending gas alarms.

Maximum Gas Exposure Tracking

Explains how the detector records, stores, and allows viewing of maximum gas exposure events.

Calibration and Data Transmission

Calibrating the Oxygen (O2) Detector

Provides instructions for performing regular calibration of the Oxygen sensor.

Gas Event Data Transmission

Explains the methods and procedures for transmitting stored gas event data.

Technical Specifications and Accessories

Available Accessories

Lists optional accessories for the GasAlertClip Extreme detector and their part numbers.

General and Safety Specifications

Lists key technical, safety, and operational specifications of the detector.

Event Logging Specifications

Outlines the capacity and types of data stored for event logging and transmission.

Support and Warranty

Contacting BW Technologies

Provides contact phone numbers, email, and address for technical support and inquiries.

Limited Warranty Details

Explains the warranty coverage, duration, limitations, and buyer's obligations.

Related product manuals