EasyManua.ls Logo

BWT Aquameter - Installation; Sensor Unit Installation; Important Installation Notes

BWT Aquameter
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Sensor unit:
For initial installation, first attach the filter head (see Installation and
Operating Instructions, “bestmax” installation section)
If a pre-installed filter system is already in place, remove the hose
on the exit side of the filter head by loosening the nut.
Attention:
The water supply to the filter system must be disconnected.
For disassembly, use an appropriate tool (flat wrench, 19 mm).
Screw the sensor unit with the gasket included in delivery
(placed in the nut) directly to the filter head.
5. Installation
Note:
Observe the direction of flow (arrow)
For assembly, use an appropriate tool (flat wrench, 19 mm).
Fasten the hose with gasket (placed in the nut) to the exit side of the sensor unit
(observe the direction of the arrow).
Important:
Ensure that
the installed lengths of the Aquameter and the bending radius of the hoses are adhered to!
the flow direction (indicated on the filter head) is adhered to!
the measuring unit is installed horizontally!
the appliance is not exposed to any mechanical strain!
sealing and connecting elements are only used if they are suitable for the provided operating conditions!
the piping is braced in front of and behind the appliance!
the system is ventilated before the start of operation!
EBA Aquameter 5.indd 10 09.02.2011 13:36:11