EasyManua.ls Logo

BWT Fairland IPHCR15 - User Manual

BWT Fairland IPHCR15
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1 / 18
2018/12 B - Code : 33315
BWT FAIRLAND
INVERTER PLUS
Pompe à chaleur
IPHCR15 - IPHCR20 - IPHCR26 - IPHCR33
- IPHCR40 - IPHCR45 - IPHCR55 - IPHCR70
- IPHCR70T - IPHCR100T

Questions and Answers

  • S
    Stacey RichardAug 3, 2025
    Why is my BWT Fairland IPHCR15 Inverter running but not heating the pool?
    • B
      Brent BakerAug 3, 2025
      If your BWT Inverter isn't heating the pool water, even when running, it could be due to several factors. High heat loss might be the cause, so ensure the pool is covered when not in use, the pipes are buried or lagged correctly, and the pool walls of above-ground pools are well-insulated. Also, check if the filtration timer is set adequately, avoiding short cycles or nighttime-only operation. Exceptionally low ambient air temperatures can also affect heating, so waiting for warmer weather may help. Lastly, ensure proper air circulation by cleaning the evaporator fins.
  • E
    Elizabeth HawkinsAug 17, 2025
    How to troubleshoot a BWT Fairland IPHCR15 Inverter that won't start?
    • L
      Lori SmithAug 18, 2025
      If your BWT Inverter heat pump won't start, first, check that no circuit breakers have tripped and that all electrical connections are secure. If the power supply is OK, make sure the unit is turned on by pressing the On/Off button. Finally, verify that the set point temperature is appropriately configured by comparing it with the inlet water temperature.

Summary

Product Installation

Siting Guidelines

Guidelines for selecting an outdoor installation location, considering clearance and proximity.

Support and Stability Requirements

Requirements for stable, solid, horizontal base and noise abatement for the heat pump.

Handling and Storage Procedures

Instructions on how to lift and store the heat pump, avoiding damage during transport or storage.

Hydraulic Circuit Connection

Details on connecting the heat pump to the filtration circuit bypass and chemical treatment systems.

Electrical Wiring Specifications

Guidance on electrical wiring by a qualified professional, including circuit breaker and cable specifications.

Heating Priority Configuration

Configuration to enable the heat pump to start filtration for heating demand detection.

Start Up and Operation

Screen Lock and Unlock

Procedure to lock and unlock the heat pump's control screen for preventing accidental changes.

Operating Function Selection

Explanation of heating, cooling, and auto modes and how the machine adapts to water temperature.

Set Temperature Adjustment

How to adjust the desired water temperature on the control panel using the up/down arrows.

Operating Mode Selection

Details on 'Smart' and 'Silence' operating modes and their respective characteristics.

Defrosting Cycle Operation

Description of the automatic defrosting cycle detection and operation for heating and auto modes.

Upkeep and Maintenance

Winterizing Procedure

Steps for preparing the heat pump for winter, including power cut, draining, and covering.

Annual Technical Inspections

Requirements for annual inspections by a qualified technician, focusing on connections and refrigerant leaks.

Spare Parts Information

Information on the availability of spare parts for Fairland heat pumps for at least 5 years.

BWT Fairland IPHCR15 Specifications

General IconGeneral
BrandBWT
ModelFairland IPHCR15
CategoryInverter
LanguageEnglish