Summary

Warning

User safety

Highlights critical instructions for user safety using a specific symbol.

Authorized persons

Specifies that the appliance is not for unsupervised use by persons with reduced capabilities.

Product delivery and general conditions of use

Details handling risks during delivery, intended use, and adherence to instructions.

Storage, shipping and packing

Storage, shipping and packing

Guidelines for packing and storing the appliance to prevent damage and maintain warranty.

Standards

Details the CE standard conformity and relevant safety regulations for BWT pool heat pumps.

Safety

Highlights potential dangers such as electrically controlled parts and moving parts.

Pressure controller

Informs about the HP pressure controller setting on BWT heat pumps.

Utilization limits

Specifies operating temperature ranges and conditions for optimal heat pump performance.

Installation

Installation conditions

Requirements for installing the heat pump, including location and clearances.

Installation location

Guidance on selecting a suitable outdoor location for the heat pump installation.

To improve your installation

Tips for optimizing installation, such as airflow management and vibration isolation.

Hydraulic connections

Hydraulic connections

Details on connecting the heat pump to the pool filtration circuit via a by-pass.

Electrical connections

Power supply connector

Power supply connector

Diagram and explanation of the power supply connector terminals and wiring.

Heating priority

Wiring connections

Instructions for connecting the filtration pump to the heat pump for heating priority control.

Parameter to confirm heating priority

Guidance on checking the setting for heating priority parameter #9.

Utilization

Water connection

Steps for connecting the heat pump to the pool water circuit and initial startup procedures.

Regulation (digital controller)

Normal display in heating mode

Explains the normal display when the heat pump is in heating mode.

All icons available

Overview of all icons that can be displayed on the digital controller.

Buttons below the display

Identifies the function of the buttons located below the display.

ON;OFF

Details how to switch the machine ON/OFF via the controller.

Working modes

Describes how to change and select different operating modes (Smart, Eco, Boost).

Time setting

Instructions on how to set the time on the digital controller.

Water temperature setting

Water temperature setting

Procedure for setting the desired water temperature using the controller.

Working information

Explanation of symbols indicating water flow, fan, compressor, and defrost status.

Water flow detection

Water flow detection

Explains how the heat pump detects water flow and the meaning of the 'flow' LED.

Internal parameters

Internal parameters

Information on accessing and checking internal parameters, recommended for professionals.

Controller state table

A table detailing error codes (Screen, Explanation, Check, Solution).

Wi-Fi module

Wi-Fi module

Instructions for downloading the app and connecting the heat pump via Wi-Fi.

App Download and Device Pairing

Steps for downloading the 'Smart Life' app, creating an account, and pairing the heat pump.

Wi-Fi Connection Process

Initiate Pairing

Press the Wi-Fi module button for 5 seconds to start the pairing process.

Enter Wi-Fi Credentials

Enter network name and password in the app, then confirm.

Connection Confirmation

Wait for the countdown and confirmation that the heat pump is connected.

Water flow setting

Water flow setting

Adjusting water flow via the by-pass valve for optimal heat pump performance.

Normal pressure

Specifies the ideal water flow rate for maximum heat transfer.

Abnormal pressure

Troubleshooting abnormal pressure by adjusting water flow with the by-pass.

Frequency of settings

When and how often to check and adjust water flow settings.

Winter setting

Winter setting

Procedure for winterizing the pool system and protecting the heat pump.

Water quality

Water quality

Specifies recommended chlorine concentration and pH levels for water quality.

Heating

Temperature rise phase

Steps for restarting the swimming pool and heat pump at the beginning of the season.

Maintaining the temperature

Guidance on reducing filtration period and maintaining pool temperature.

Maintenance (by a qualified technician)

Monthly checks

List of checks to be performed on a monthly basis for maintenance.

Yearly checks

List of checks to be performed on a yearly basis for maintenance.

After Sales Technical Service

Information required for technical support and troubleshooting.