7.2 The lter pressure rises 0.3 bar or more above that indicated by
the red needle of the pressure gauge
the lter needs to be cleaned
Stop the pump,
Check that the prelter is clean (remove any build up of dirt as described previously),
Switch the multiport valve to «BACKWASH»,
Turn the motor on,
Monitor the colour of the water through the transparent section of the drain union
Caution, there will be a lapse of a few seconds before cleaning starts (water becomes very cloudy),
As soon as the water in the transparent section of the drain union runs clear, stop the pump,
Switch the multiport valve to «RINSE»,
Turn the pump on for 20 to 30 seconds, this is to remove any dirt or debris remaining in the main valve and
settle the sand,
Stop the pump,
Switch the multiport valve to «FILTRATION»,
Turn the pump on.
After backwashing the black needle should re-align with the red needle that marks the lter’s nominal
pressure.
If after one backwash (or even two), the pressure does not drop back to the nominal pressure, call your
installer.
8. WINTERIZING
Carry out a prolonged backwash of the lter,
Treat the pool water,
Stop the pump,
Switch the multiport valve to «DRAIN»,
Turn the motor on,
Lower the water level by approximately 30 cm,
Empty the lter by opening the lower drain,
Close all the valves,
Unscrew the motor drain plugs,
Disconnect the electrical supply at the switch box,
Store the motor in a dry place.