4. INSTRUCTIONS FOR POSITIONING AND CLOSING THE
LID
Hold the lid over the lter tank. Press the lid into the lter tank at one point. Using
your knee, maintain pressure on this point.
Position your two hands on the lid such that they
are equidistant both from each other and your knee
(120° angle).
Bear down simultaneously with both hands to
push the lid completely into the lter tank. Maintain
pressure on the lid until the ring is screwed into
position.
Connect the lter to the pump and pool suction and
returns according to the diagram opposite.
Push the tubes onto the barbed unions until they
reach the boss (bump) marking the stop point.
The drain union is transparent, the clear section can
thus act as a sight glass to assess turbidity.
To stop the trickle from the drain (normal for a lter
in operation), install a 1/4 turn valve on the drain
line.
Use the hose clips provided to make the unions
leaktight.
Filtered water outlet
Pump/ filter connection
Drain
Non-filtered
water inlet
17/32
2021/01 - Indice de révision : G - Code : 26650FILTRATION