2. SITING
The ltration group must be installed on a at, level surface and at a distance of at least 3,5 m from the water
(French standard C15-100). The electrical supply must be protected by 30mA di󰀨erential circuit breaker.
The lter group should be installed close to a drain or waste line to facilitate evacuation of backwash water.
3. LOADING THE FILTER MEDIA
1
Unscrew and remove the ring.
2
Remove the lid/valve assembly (positioned upside-
down during transport).
3
Glueing the unions to the lid: The transparent union
to the waste outlet, the black or grey unions to the
pump inlet and outlet.
Caution: avoid using excess glue, this could
dammagethevalve
4
Screw in the drain plug.