5
Check that the collector plate is correctly positioned
at the bottom of the lter tank. Insert the collector
pipe (topped with its plug) into the hole in the middle
of the collector plate.
6
Carefully pour the sand into the lter and,using
your hand, spread it out evenly.
Quantityofsand
P-FI 400 20 Kgs
P-FI 500 50 Kgs
Grain size 0.6 / 1.25
7
Installing the pressure gauge: Place the o-ring in its
groove in the cover.
8
Position the pressure gauge correctly and place it
in its housing.
15/32
2021/01 - Indice de révision : G - Code : 26650FILTRATION