GENERAL OPERATION TROUBLESHOOTING GUIDE
Problem Probable causes Solutions
Entire spa is inoperative Power failure
GFCI tripped
Heater high-limit thermostat tripped
Spa lock activated
Check power source
Reset GFCI; call for service if it will not reset
Disconnect power for at least thirty seconds to reset heater high limit. If it will not
reset, check for clogged filters. If tripping continues, call for service.
Deactivate spa lock
Spa does not heat; jets and light
operate (Orange logo "Ready", and
Gray logo "Power" indicators are
blinking)
Integrated pressure switch open
Circulation pump thermal cut-off tripped
Check for clogged filters. Integrated pressure switch will reset when the flow of water
through the heater has been restored. Call for service if the heater trips frequently.
Check for clogged filters or air locks in plumbing. Disconnect power to the spa, allow
circulation pump to cool. Circulation pump thermal cut-off will reset when pump has
cooled and power is reapplied. Call for service if circulation pump thermal cut-off
trips frequently.
Jets weak or surging Spa water level too low
Filters clogged
Air valves are closed
Add water
Clean filters
Open air valves
Lights inoperative
Spa lock activated
Light wiring or assembly is faulty
Deactivate spa lock
Call for service, replace light assembly
Spa not heating properly Temperature set too low
Spa cover improperly positioned
Dirty Filter
Summer Timer On
Set control panel to a higher temperature.
Align spa cover
Clean filter
Turn summer timer mode to off position
Gray Logo "Power" indicator blinking Heater high-limit thermostat tripped Disconnect power for at least thirty seconds to reset heater high limit. If it will not
reset, check for clogged filters. If tripping continues, call for service.
Orange Logo "Ready" indicator
blinking
Temperature sensor problem Disconnect power for at least thirty seconds. If blinking continues, call for service.
Pump motor will not function Motor overload condition
Control switch failure if jet symbol does not
come on
Let cool for one hour. Motor overload will reset automatically. If problem persists,
contact your CALDERA dealer
Disconnect spa and contact your CALDERA dealer
Noisy pump or motor Low water level Add water to normal level (2.5 cm above highest jet)
Pump motor runs, but low or no water/
jet pressure
Air control valve closed or blocked
Low water level
Dirty filter cartridge
Jet blocked
Clogged suction or skimmer basket
Open or clean air valve
Add water to normal level (2.5 cm above highest jet)
Clean filter cartridge
Remove jet face eyeball and clean orifice
Clean suction cover or skimmer basket
Diverter valves are difficult to turn
Sand or grit inside valves
Clean and lubricate valve per diverter valve maintenance instructions.
After filling or refilling the spa: a jet
pump is operating, but water is not
flowing from any of its jets
Pump is not properly primed
Turn off power to the spa at the breaker and remove the equipment compartment
door.
Loosen the union on the top of the pump(s) to allow the air to escape, and then
hand-tighten the union(s).
Turn power back on, activate the pump, and check to make sure the union is tight
enough to keep it from leaking. Replace the equipment doors.
OR: Remove and reinstall the FROG cap.