Standalone Keypad/Prox Access Control
Alarm output time
To set the alarm output time (0~3 minutes) Factory
default is 1 minute
5 0~3 #
Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers in a
10 minute period either the keypad will lockout for 10 minutes or the alarm will operate for 10 minutes,
depending on the option selected below.
Normal status: No keypad lockout or alarm
(factory default)
7 0 # (Factory default setting)
Keypad lockout enable 7 1 #
Alarm and inside buzzer enable 7 2 #
To remove the alarm
To reset the Door Forced Open Alarm
Read valid card or Master Code #
To reset the Door Propped Open Alarm
Close the door or Read valid card or
Master Code #
Page 7 of 8
Relay Output Dealy Time
To set door relay strike time
* Master code # 4 0~99 # *
0-99 is to set the door relay time 0-99 seconds
Door Open Detection
Door Propped Open Alarm. When used with an optional magnetic contact or built-in magnetic
contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep
automatically to remind people to close the door and continue for 1 minute before switching off automatically.
Door Forced Open Alarm. When used with an optional magnetic contact or built-in magnetic contact of the lock, if
the door is opened by force, or if the door is opened after 20 seconds of the electro-mechanical lock not closing
properly, the inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between 0~3
minutes with the default being 1 minute.
To disable door open detection. (Factory default) 6 0 #
To enable door open detection 6 1 #