5.10 Adjusting end-stops with encoder
Before beginning to make adjustments
on the end-stop, execute the run calibra-
tion procedure described in the technical
manual of the command board.
After calibrating, the door must be in a
closed position and the crown wheel on
the motor unit must be positioned to the
left.
Raise the end-stop spring unhooking it
from the support bracket and lower it
onto the crown wheel.
Important! For gearmotors installed on
sliding and folding doors, never unhook
the end-stop spring from the support
bracket.
Ensure that the release lever is free from
the safety lever.
NB: the safety lever releases the
emergency release (CMS or C002) only
with the door closed.
Important! For gearmotors installed on
sliding and folding doors, remove the
security lever and respective spring.
Crown wheel
End-stop spring
Support bracket
Safety lever