Functions map
F 1 Total stop function (1-2)F 2 Function associated to input CX
F 3 Function associated to input CY
F 5 Safety test function
F 6 Maintained action function
F 7 Control mode on 2-7
F 9 Obstruction detection with motor idle function
F 10 Warning light function
F 15 Intermittent luminous cord function
F 19 Automatic closing time
F 21 Preflashing time
F 22 Working time
F 28 Adjusting opening speed
F 29 Adjusting closing speed
F 30 Adjusting opening slow-down speed
F 31 Adjusting closing slow-down speed
F 33 Adjusting calibration speed
F 34 Sensitivity during movement
F 35 Sensitivity during slow-down
F 37 Adjusting the opening slow-down starting point
F 38 Adjusting the closing slow-down starting point
U 1 Type of command to associate to a user via radio control
U 2 Deleting single users
U 3 Deleting all users
A 1 Setting the boom type
A 2 Motor test
A 3 Calibrating boom travel
A 4 Resetting parameters
A 5 Counting the number of maneuvers
H 1 Software version
IMPORTANT! Start programming by first performing the following: A1 BOOM-TYPE SETTING, A2 MOTOR TEST,
F1 TOTAL STOP and A3 CALIBRATING BOOM TRAVEL.
Functions menu
F1 Total stop [1-2] 0 = Deactivated / 1 = Activated (default)
NC input - boom stop while excluding any automatic stop; to resume movement, use the control device. The safety device is to be fi tted into
[1-2]. If unused, deactivate the function.
F2 Input [2-CX] 0 = Deactivated (default) / 1 = C1 / 4 = C4 / 5 = C5 / 9 = C9
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by photocells, C3 = partial stop, C4 =
obstruction wait, C5 = immediate closing, C9 = immediate closing with obstruction wait during closing.
F3 Input [2-CY] 0 = Deactivated (default) / 1 = C1 / 4 = C4 / 5 = C5 / 9 = C9
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by photocells, C3 = partial stop, C4 =
obstruction wait, C5 = immediate closing, C9 = immediate closing with obstruction wait during closing.
F5 Safety test 0 = Deactivated (default) / 1 = CX / 2 = CY / 3 = CX+CY
After every opening or closing command, the control board will check whether the photocells are working properly.
F6 Maintained action 0 = Deactivated (default) / 1 = Activated
The barrier opens and closes by keeping one button pressed. Opening button on 2-3 and closing button on 2-4. When this function is
activated, all other control devices, even radio ones, are excluded.
F7 Command [2-7] 0 = step-step (default) / 1 = sequential
Step-step = open-close, sequential = open-stop-close-stop.