F9 Obstruction detection with motor idle 0 = Deactivated (default) / 1 = Activated
With the barrier closed, open or after a total stop, the operator stays still if the safety devices (photocells and sensitive edges) detect an
obstruction.
F10 Warning light 0 = lit with boom raised and moving (default) /
1 = fl ashes intermittently each half second when opening
when closing it fl ashes intermittently every second
permanently lit with the boom raised
o with the boom lowered
It warns of the barrier status. The light bulb is connected to 10-5.
F 15 Luminous cord intermittance 0 = Moving boom (default) /1 = Moving and closed boom
It warns of the status of the barrier with intermittent lights.
F19 Automatic closing time 0 = Deactivated (default) / 1 = 1 s / 2 = 2 s / … / 180 = 180 s
The fi rst automatic-closing wait starts when the opening limit-switch point is reached and can be set to between 1 and 180 seconds. The
automatic closing does not turn on if any of the safety devices trigger when an obstruction is detected, after a total stop or during a power
outage.
F21 Prefl ashing time 0 = Deactivated (default) / 1 = 1 s / … / 10 = 10 s
After an opening or closing command, the fl ashing light connected to 10-E6, fl ashes from 1 to 10 seconds before the maneuver starts.
F22 Working time 5 = 5 s / ...../ 120 = 120 s (default)
Gearmotor working time during opening and closing.
The working time can be adjusted between 5 and 120 seconds.
F28 Opening maneuver speed 60 = Minimum speed /… /80 = Speed (default) /.... / 100 = Maximum speed.
Setting the boom's opening speed, calculated as a percentage.
⚠
Setting the speed between 90 and 100 automatically increases the percentage of the F 37 opening slow-down starting point.
F 29 Closing maneuver speed 60 = Minimum speed /… /80 = Speed (default) /.... / 100 = Maximum speed.
Setting the boom's closing speed, calculated as a percentage.
⚠
Setting the speed between 90 and 100 automatically increases the percentage of the F 38 closing slow-down starting point.
F 30 Opening slow-down speed 10 = Minimum speed /…/ 15 = Speed (default) /..../ 30 = Maximum speed
Setting the boom's opening slow-down speed, calculated as a percentage.
F31 Closing slow-down speed 10 = Minimum speed /…/ 15 = Speed (default) /..../ 30 = Maximum speed
Setting the boom's closing slow-down speed, calculated as a percentage.
F33 Calibration speed 10 = 10% of the travel (minimum) / … / 20 = 20% of the travel (default) /..../ 30 = 30% of the travel
(maximum)
Setting the boom's travel automatic calibration, calculated as a percentage
F34 Boom travel sensitivity 10 = maximum sensitivity / … / 100 = minimum sensitivity (default)
Adjusting obstruction detection sensitivity during boom travel.
F35 Slow-down sensitivity 10 = maximum sensitivity / … / 100 = minimum sensitivity (default)
Adjusting obstruction detection sensitivity during slow-down.
F37 Opening slow-down point 40 = 40% of the travel / … / 50 = 50% of the travel (default) /… / 70 = 70% of the travel
Percentage adjustment of the boom's total travel, from the beginning of the opening slow-down point.
F38 Closing slow-down point 40 = 40% of the travel / … / 50 = 50% of the travel (default)
/… / 60 = 60% of the travel
Percentage adjustment of the boom's total travel, from the beginning of the opening slow-down point.
U 1
Entering a user 1 = Step-step command (open-close) / 2 = Sequential command (open-stop-close-stop) / 3 = Open only command
IUp to a maximum of 25 users can be entered and each can be associated to a function of choice among those available. Entering is done via
transmitter or other control device (see ENTERING USERS AND ASSOCIATED COMMANDS)
U 2 Deleting a user
To delete a user (see DELETING SINGLE USERS paragraph)
U 3 Deleting users 0 = Deactivated / 1 = Deleting all users
Deleting all users.