- 05/2015 - © Came S.p.A. The data and information in this manual may be changed at any time and without notice.
A 1 Setting the boom type 0 = Ø 60 mm tube boom / 1 = Semi-elliptic or elliptic boom
To establish the boom type.
A 2 Motor test 0 = Disable / 1 = Activate
To verify the boom's proper rotating direction (see MOTOR TEST paragraph).
A 3 Calibrating boom travel 0 = Disable / 1 = Activate
Automatic boom travel calibration (see CALIBRATING BOOM TRAVEL paragraph).
A 4 Resetting parameters 0 = Disable / 1 = Activate
Warning! If need be, the default parameters can be restored.
The default settings are restored and the travel calibration deleted.
Restoring default settings and cancelling boom travel calibration operation.
A 5 Counting maneuvers
Show the number of completed maneuvers(--- = 0 maneuvers; 1 = 1,000 maneuvers; 100 = 100,000 maneuvers; ........... 999 = 999,000).
H 1 Version
View the software version.
Motor test
1. Select A 2. Press ENTER to confirm.
2. Select 1 to activate test. Press ENTER to confirm...
3. ... the dashes (---) will appear while waiting for the command.
4. 4. Keep pressed the < key and check whether the barrier
opens.
If the barrier closes, invert the motor phases (M with N).