If the key is not enough to release the boom from the gearmotor, you will have to remove the dome, open the inspection hatch and
pull on the release lever under the transformer .
Manually lift the boom and lock it again by moving back the lever .
Er1 The boom travel calibration was interrupted by the activation of the STOP button.
Er3 Encoder is broken.
Er4 Services test error.
Er5 Insufficient working time
Er6 Maximum number of obstructions detected.
Er7 Overheating of transformer / inspection hatch open / boom released from gearmotor.
Er8 The inspection hatch is open.
C0 Contact 1-2 (NC) is open.
C1, C4, C5 or C9 The (NC) contacts are open.
The warning LED
flashes
The control board is not yet calibrated for the boom travel.
ERROR MESSAGE
The error messages appear on display or are notified by the LEDs
.