F
i
A2
0
i
ENTER
>
>
ENTER
>...>
F
i
i
2
ENTER >
>
ENTER
>...>
A I
ENGLISH
p.
18 - Manual code:
119G 3 565 E N ver.
2.0 09/2012 © CAME Cancelli Automatici S.p.A. - The data and information in this manual may be changed at any time and without prior warning.
Menu map
F 1 Total stop function (1-2)
F 2 Function associated to input 2-CX
F 3 Function associated to input 2-CY
F 19 Automatic closing time
F 21 Pre-flashing time
F 28 Adjusting opening speed
F 29 Adjusting the closing speed
F 30 Adjusting the slow-down speed when opening
F 31 Adjusting closing-slow-down speed
F 33 Adjusting calibration speed
F 34 Sensitivity during movement
F 35 Sensitivity during slow down
F 37 Adjusting the beginning slow-down point of the motor when opening
F 38 Adjusting the beginning slow-down point of the motor when closing
F 39 Adjusting the beginning opening strike point of the motor
F 40 Adjusting the beginning closing strike point of the motor
F 49 Combo connection functions
F 50 Saving data in the memory roll
F 51 Reading memory roll data
F 52 Passing parameters from MASTER TO SLAVE
F 53 Anti-Pass-Back function
F 54 Direction choice function associated to the Anti-pass-back function
F 55 Alarm activation function
F 56 Setting the number of the peripheral
F 57 Limit-switch closing offset functions
U 1 Adding a new user
U 2 Cancelling one user
U 3 Completely cancel users
A 1 Leaf type
A 2 Motor testand
A 3 Calibrating travel
A 4 Reset parameters
H 1 Software version
A 2 (Motor test):
activate the test to check whether the turnstile works properly (see the paragraph about motor test).
0 = Deactivated; 1 = Activated.
Confirm with the ENTER button after choosing the value for each feature.
Motor test and calibration menu
A 1 (Wing barrier type) : defining the wing barrier.
Note: the choice of wing-barrier type limits some parameters in terms of speed, end strikes, and the such. This
ensures the proper functioning of the operator.
1 = glass leaf (default); 2= Plexiglas leaf.
Important! We suggest starting the programming by first doing the following:
1 Defining the wing-barrier type;
2 Motor test;
3 Calibration of travel.