Features menu
A 4 (Reset parameters):
data restoring procedure (for default settings) and travel calibration cancellation.
0 = Deactivated; 1 = Activated.
F 1 (Total Stop 1-2) - N.C. input: wing-barrier stop with possible exclusion of the automatic-closing cycle; to restore
movement act on the command device. Insert safety device on [1-C2]; if unused, set the feature to 0.
0 =Deactivated (default) 1 = Activated
F 2 (2-CX input): N.C. safety contact input (reopen while closing).
0 = deactivated (default); 1 = Activated.
F 3 (2-CY input): N.C. safety contact input (reopen while closing).
0 = deactivated (default); 1 = Activated.
F 19 (Automatic closing time): the automatic closing timer activates at the closing endpoint. The pre-set time is
adjustable, and is anyhow conditioned by a possible intervention by the safety devices and is deactivated after a total
emergency stop or when the power is cut.
The waiting time can be deactivated or adjusted from 1" to 60".
1 = 1 second (default); 2 = 2 seconds; .................. 60 = 60 seconds.
A 3 (travel calibration): automatic gate-wing travel calibrating operation (see the paragraph about calibrating travel).
0 = Deactivated; 1 = Activated.
Warning! If needed, you can restore the factory settings with the following feature: