Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
IN620503AV 11/15
See Warranty on page 12 for important information about commercial use of this product.
Operating Instructions and Parts Manual DC040000, HL540200, HL540210
© 2015 Campbell Hausfeld
A Marmon/Berkshire Hathaway Company
For parts, product & service information,
visit www.campbellhausfeld.com
Oil-Lubricated
Compressors
Description
This oil-lubricated compressor is
designed for do-it-yourselfers with a
variety of home and automotive jobs.
These compressors power spray guns,
impact wrenches and other tools.
Compressed air from this unit will
contain moisture. Install a water filter
or air dryer if application requires dry
air.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may
have occurred during transit. Make sure
to tighten fittings, bolts, etc., before
putting unit into service. In case of
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
assistance. Have the serial number,
model number, and parts list (with
missing parts circled) before calling.
DO NOT RETURN
THE PRODUCT TO
THE RETAILER!
Do not operate unit
if damaged during
shipping, handling or use. Damage may
result in bursting and cause injury or
property damage.
READ & FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
DO NOT DISCARD
Caution indicates
a potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed,
may cause damage to equipment.
NOTE: Information that requires special
attention.
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, WILL result in death or
serious injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, COULD result in death
or serious injury.
Breathable Air Warning
This compressor / pump is not
equipped and should not be
used “as is” to supply breathing
quality air. For any application of
air for human consumption, the
air compressor / pump will need
to be fitted with suitable in-line
safety and alarm equipment.
This additional equipment is
necessary to properly filter
and purify the air to meet
minimal specifications for
Grade D breathing as described
in Compressed Gas Association
Commodity Specification
G 7.1 - 1966, OSHA 29 CFR 1910.
134, and / or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is
used for the purpose of breathing
air application and proper in-line
safety and alarm equipment is
not simultaneously used, existing
warranties shall be voided, and
the manufacturer disclaims any
liability whatsoever for any loss,
personal injury or damage.
STOP!
Record the Model No., Serial No. and
date of purchase located on the base
below the pump in the space below.
Model No. ________________________
Serial No. _________________________
Date of purchase _________________
Retain these numbers for
future reference.

Questions and Answers

  • C
    colemanamberAug 14, 2025
    Why Campbell Hausfeld Air Compressor will not run?
    • K
      Kathleen WoodAug 14, 2025
      Your Campbell Hausfeld air compressor might not be running due to several reasons. It could be due to a lack of electrical power—ensure it's plugged in and switched on, and check the fuse or breaker. The breaker might be open, in which case you should reset it and determine the cause of the problem. A faulty pressure switch could also be the culprit, requiring replacement. If the motor is overworked, turn it off, let it cool, and then turn it back on. Finally, if the tank pressure is above the cut-in point, bleed the tank pressure down to the cut-in level.
  • E
    Edward SmithAug 21, 2025
    Why does my Campbell Hausfeld DC040000 Air Compressor shut off unexpectedly or won't start?
    • P
      Pedro NavarroAug 21, 2025
      Your Campbell Hausfeld air compressor might be shutting off unexpectedly or failing to start due to several reasons. The circuit could be overloaded, so disconnect other appliances or operate the compressor on its own circuit. Low voltage could be the issue; check the voltage at the wall outlet. Incorrect extension cord usage could also be a factor; remove the extension cord. Check for loose electrical connections. Other potential causes include a worn check valve, a defective unloader valve, defective motor capacitor(s), or a defective motor, all of which would need replacing. Lack of proper ventilation or a room temperature that's too high can also cause this; move the compressor to a well-ventilated area. Lastly, a clogged intake filter could be the problem; clean or replace the filter.
  • V
    vjonesAug 25, 2025
    Why does my Campbell Hausfeld DC040000 Air Compressor keep blowing fuses / circuit breaker trips repeatedly?
    • R
      Rhonda StricklandAug 25, 2025
      If your Campbell Hausfeld air compressor is causing fuses to blow or the circuit breaker to trip repeatedly, it could be due to a few reasons. You might be using an incorrect size fuse or the circuit is overloaded; check for the proper fuse and use a time-delay fuse. Try disconnecting other electrical appliances from the circuit or operate the compressor on its own dedicated branch circuit. Incorrect extension cord usage could also be the problem. A worn check valve, defective unloader valve, defective motor capacitor(s), or a defective motor could also be responsible, all of which would require replacement.
  • J
    John TorresAug 28, 2025
    What to do if my Campbell Hausfeld DC040000 tank pressure drops when compressor shuts off?
    • A
      Amy HarrisAug 28, 2025
      If the tank pressure drops after your Campbell Hausfeld air compressor shuts off, it could be due to a few reasons. Check for loose connections (fittings, tubing, etc.) using a soap and water solution, then tighten them, or remove and apply pipe dope or pipe tape to the threads before reassembling. Make sure the tank drain valve is closed. Also, inspect the tank for leaks using a soap and water solution; if a leak is detected, the tank must be replaced. Finally, a worn check valve can cause this issue, requiring replacement.
  • J
    Joshua BarkerAug 31, 2025
    Why is there excessive moisture in the discharge air of my Campbell Hausfeld DC040000?
    • K
      Kiara BoydAug 31, 2025
      Excessive moisture in the discharge air of your Campbell Hausfeld air compressor can be attributed to a couple of factors. There might be excessive water in the tank, in which case you should drain the tank. High humidity can also contribute; consider moving the compressor to an area with less humidity or using an air line filter.
  • P
    Patrick Mueller IISep 3, 2025
    What causes knocks, rattles, and/or excessive vibration in my Campbell Hausfeld DC040000 Air Compressor?
    • B
      Brady ChaneySep 3, 2025
      Knocks, rattles, or excessive vibration in your Campbell Hausfeld air compressor can stem from loose mounting bolts; tighten them. Another cause could be that the tank is not level; use a sturdy wedge or object to bring the tank to a level position.
  • R
    Rebecca AllenSep 7, 2025
    Why does my Campbell Hausfeld DC040000 run continuously and safety valve opens as pressure rises?
    • M
      Michael WellsSep 7, 2025
      If your Campbell Hausfeld air compressor runs continuously and the safety valve opens as the pressure rises, it could be because the cylinder or piston is worn or scored. You should replace or repair them as necessary.
  • R
    Rachel GonzalezSep 10, 2025
    Why is air leaking from the unloader valve on the pressure switch of my Campbell Hausfeld Air Compressor?
    • E
      Eddie GambleSep 12, 2025
      Air leaking from the unloader valve on the pressure switch of your Campbell Hausfeld air compressor could be due to a defective pressure switch, which would need replacement. It could also be caused by a defective safety valve, which should be replaced with a genuine replacement part. Another possible cause is a check valve stuck in an open position, which also requires replacement. Finally, the unloader valve itself might be stuck open, necessitating its replacement.
  • I
    Ian IngramNov 17, 2025
    What to do if my Campbell Hausfeld DC040000 Air Compressor runs continuously and / or air output is lower than normal / low discharge pressure?
    • K
      Kayla TaylorNov 17, 2025
      If your Campbell Hausfeld air compressor runs continuously and the air output is lower than normal, it could be due to several reasons. First, there might be excessive air usage, indicating the compressor isn't large enough for the air requirement, so decrease air usage. The intake filter might be clogged, requiring cleaning or replacement. Ensure the tank drain valve is closed. Air leaks in the piping, either on the machine or in the outside system, can also cause this issue; check all connections with a soap and water solution, tighten them, or remove and apply pipe dope or pipe tape to the threads before reassembling. Other potential causes include a worn piston ring (replace the piston and cylinder), a broken valve in the pump (replace the valve), tank leaks (check with soap and water ...

Campbell Hausfeld DC040000 Specifications

General IconGeneral
Max Pressure125 PSI
Tank Size4 Gallons
Power SourceElectric
Weight42 lbs
Voltage120 V
Pump TypeOil-Free
Noise Level68 dBA
Horsepower0.8 HP (Peak)

Related product manuals